Shear Behaviour of Novel U‐connector in CFS Truss‐to‐Column Connection
AbstractThis research investigates the behaviour of the novel U‐connector used in cold‐formed steel (CFS) truss‐to‐column connection. The novelty is reflected in the specially designed connector geometry and the connection method within the cross‐section of the thin‐walled C‐profile. The U‐connector installed inside the truss‐to‐column connection can be exposed to tensile, compressive and shearing action. The shear behaviour of the U‐connector is thoroughly investigated using laboratory tests. Three different loading scenarios are carried out to evaluate the shear strength of the U‐connector within the C‐profile connection. The detailed analysis is carried out using Digital Image Correlation (DIC) technique for measuring the displacement. The failure modes observed during the experiments are described and analysed. DIC technology is used to accurately identify the failure initiation of each component in the connection. In addition, two different methods for calculating the bearing resistance of the U‐connector and the C‐profile connection are proposed according to recommendations given in the standard EN 1993‐1‐3. These methods aim to provide accurate estimates of the connection's bearing capacity.
Shear Behaviour of Novel U‐connector in CFS Truss‐to‐Column Connection
AbstractThis research investigates the behaviour of the novel U‐connector used in cold‐formed steel (CFS) truss‐to‐column connection. The novelty is reflected in the specially designed connector geometry and the connection method within the cross‐section of the thin‐walled C‐profile. The U‐connector installed inside the truss‐to‐column connection can be exposed to tensile, compressive and shearing action. The shear behaviour of the U‐connector is thoroughly investigated using laboratory tests. Three different loading scenarios are carried out to evaluate the shear strength of the U‐connector within the C‐profile connection. The detailed analysis is carried out using Digital Image Correlation (DIC) technique for measuring the displacement. The failure modes observed during the experiments are described and analysed. DIC technology is used to accurately identify the failure initiation of each component in the connection. In addition, two different methods for calculating the bearing resistance of the U‐connector and the C‐profile connection are proposed according to recommendations given in the standard EN 1993‐1‐3. These methods aim to provide accurate estimates of the connection's bearing capacity.
Shear Behaviour of Novel U‐connector in CFS Truss‐to‐Column Connection
ce papers
Lukačević, Lazar (Autor:in) / Krolo, Paulina (Autor:in) / Bakran, Antonio (Autor:in) / Palijan, Ivan (Autor:in)
ce/papers ; 6 ; 1995-2000
01.09.2023
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Shear Connector Design of Steel Belt Truss-to-Concrete Mega Column Connection
Online Contents | 2017
|Performance of Novel U-Connector in CFS Truss-to-Column Bolted Connection under Axial Force
DOAJ | 2023
|