Two‐Level Multivariable Control System of Dissolved Oxygen Tracking and Aeration System for Activated Sludge Processes
The problem of tracking dissolved oxygen is one of the most complex and fundamental issues related to biological processes. The dissolved oxygen level in aerobic tanks has a significant influence on the behavior and activity of microorganisms. Aerated tanks are supplied with air from an aeration system (blowers, pipes, throttling valves, and diffusers). It is a complex, dynamic system governed by nonlinear hybrid dynamics. Control of the aeration system is also difficult in terms of control of the dissolved oxygen. In this article, a two‐level multivariable control system for tracking dissolved oxygen and controlling an aeration system is designed. A nonlinear model predictive control algorithm was applied to design controllers for each level. This overall hierarchical control system was validated by simulation based on real data records provided by a water resource recovery facility located in Kartuzy, Northern Poland. The effect of control system parameters and disturbances was also investigated.
Two‐Level Multivariable Control System of Dissolved Oxygen Tracking and Aeration System for Activated Sludge Processes
The problem of tracking dissolved oxygen is one of the most complex and fundamental issues related to biological processes. The dissolved oxygen level in aerobic tanks has a significant influence on the behavior and activity of microorganisms. Aerated tanks are supplied with air from an aeration system (blowers, pipes, throttling valves, and diffusers). It is a complex, dynamic system governed by nonlinear hybrid dynamics. Control of the aeration system is also difficult in terms of control of the dissolved oxygen. In this article, a two‐level multivariable control system for tracking dissolved oxygen and controlling an aeration system is designed. A nonlinear model predictive control algorithm was applied to design controllers for each level. This overall hierarchical control system was validated by simulation based on real data records provided by a water resource recovery facility located in Kartuzy, Northern Poland. The effect of control system parameters and disturbances was also investigated.
Two‐Level Multivariable Control System of Dissolved Oxygen Tracking and Aeration System for Activated Sludge Processes
Piotrowski, Robert (Autor:in)
Water Environment Research ; 87 ; 3-13
01.01.2015
11 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Activated-sludge aeration system