Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Chlorate, perchlorate, and bromate in onsite‐generated hypochlorite systems
This study evaluated the occurrence and temporal variability of chlorate, perchlorate, and bromate in 26 low‐strength onsite‐generated (OSG) hypochlorite systems and three high‐strength systems. None of the samples from the systems tested would have contributed more than 1 μg/L perchlorate to the finished water, even at a 10‐mg/L chlorine dose; similarly, none of the samples exceeded the NSF International specific product allowable concentration for bromate of 0.5 μg/mg free chlorine. Of the samples collected, however, 10 of the 29 unique OSG systems would have exceeded the US Environmental Protection Agency's 210‐μg/L health reference level for chlorate at a dose of only 5 mg/L chlorine, and 21 of the 29 would have exceeded 210 μg/L chlorate at the 10‐mg/L chlorine maximum use level. No apparent correlation was found between chlorate production and OSG brand, age, or capacity nor was any correlation observed between chlorate production and pH, transition metals, chloride, conductivity, or temperature.
Chlorate, perchlorate, and bromate in onsite‐generated hypochlorite systems
This study evaluated the occurrence and temporal variability of chlorate, perchlorate, and bromate in 26 low‐strength onsite‐generated (OSG) hypochlorite systems and three high‐strength systems. None of the samples from the systems tested would have contributed more than 1 μg/L perchlorate to the finished water, even at a 10‐mg/L chlorine dose; similarly, none of the samples exceeded the NSF International specific product allowable concentration for bromate of 0.5 μg/mg free chlorine. Of the samples collected, however, 10 of the 29 unique OSG systems would have exceeded the US Environmental Protection Agency's 210‐μg/L health reference level for chlorate at a dose of only 5 mg/L chlorine, and 21 of the 29 would have exceeded 210 μg/L chlorate at the 10‐mg/L chlorine maximum use level. No apparent correlation was found between chlorate production and OSG brand, age, or capacity nor was any correlation observed between chlorate production and pH, transition metals, chloride, conductivity, or temperature.
Chlorate, perchlorate, and bromate in onsite‐generated hypochlorite systems
Stanford, Benjamin D. (Autor:in) / Pisarenko, Aleksey N. (Autor:in) / Dryer, Deborah J. (Autor:in) / Zeigler‐Holady, Janie C. (Autor:in) / Gamage, Sujanie (Autor:in) / Quiñones, Oscar (Autor:in) / Vanderford, Brett J. (Autor:in) / Dickenson, Eric R.V. (Autor:in)
Journal ‐ American Water Works Association ; 105 ; E93-E102
01.03.2013
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Bromate, chlorate, chlorite and perchlorate in sodium hypochlorite solution used in water supply
Online Contents | 2009
|Bromate, chlorate, chlorite and perchlorate in sodium hypochlorite solution used in water supply
British Library Online Contents | 2009
|Perchlorate, chlorate and bromate in water samples from the South-West coast of India
Online Contents | 2012
|Chlorate Occurrence in On-Site Generated Hypochlorite: National Data (and Cost of Compliance)