Uniformity of stratum‐ventilated thermal environment and thermal sensation
Three human test series were conducted to evaluate the uniformity of the thermal environments in a stratum‐ventilated chamber with dimensions of 8.8 m (L) × 5.1 m (W) × 2.4 m (H). In all, nineteen conditions were generated by adjusting the room temperature, supply airflow rate, and supply terminal type. An air diffuser performance index (ADPI) of at least 80% was achieved for most cases. This result shows that the air velocity and temperature in the occupied zone are reasonably uniform. Subjective assessments using the ASHRAE 7‐point scale indicate that the thermal sensations of the subjects in stratum ventilation are also uniform. This study examines the applicability of the predicted mean vote (PMV) model for evaluating stratum ventilation. When compared to the actual mean thermal sensation votes (ATS), the PMV values are acceptable. The PMV results at a height of 1.1 m above the floor show better agreement with the ATS than at a height of 0.1 m.
Uniformity of stratum‐ventilated thermal environment and thermal sensation
Three human test series were conducted to evaluate the uniformity of the thermal environments in a stratum‐ventilated chamber with dimensions of 8.8 m (L) × 5.1 m (W) × 2.4 m (H). In all, nineteen conditions were generated by adjusting the room temperature, supply airflow rate, and supply terminal type. An air diffuser performance index (ADPI) of at least 80% was achieved for most cases. This result shows that the air velocity and temperature in the occupied zone are reasonably uniform. Subjective assessments using the ASHRAE 7‐point scale indicate that the thermal sensations of the subjects in stratum ventilation are also uniform. This study examines the applicability of the predicted mean vote (PMV) model for evaluating stratum ventilation. When compared to the actual mean thermal sensation votes (ATS), the PMV values are acceptable. The PMV results at a height of 1.1 m above the floor show better agreement with the ATS than at a height of 0.1 m.
Uniformity of stratum‐ventilated thermal environment and thermal sensation
Cheng, Y. (Autor:in) / Fong, M. L. (Autor:in) / Yao, T. (Autor:in) / Lin, Z. (Autor:in) / Fong, K. F. (Autor:in)
Indoor Air ; 24 ; 521-532
01.10.2014
12 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Uniformity of stratum‐ventilated thermal environment and thermal sensation
Online Contents | 2014
|SAGE Publications | 2024
|New Thermal Sensation Index for Outdoor Environment
British Library Online Contents | 1996
|Effects of temperature and supply airflow rate on thermal comfort in a stratum-ventilated room
Online Contents | 2015
|Effects of temperature and supply airflow rate on thermal comfort in a stratum-ventilated room
British Library Online Contents | 2015
|