Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Determining toxicity of leachates from Florida municipal solid waste landfills using a battery‐of‐tests approach
10.1002/tox.10053.abs
The toxicity and physicochemical parameters of municipal solid‐waste (MSW) landfill leachates from six sites in north and north‐central Florida, United States, were determined. Landfill leachates are complex mixtures of organic and inorganic constituents. Leachate toxicity was assayed using the acute C. dubia (48‐h) and Microtox™ (15‐min) assays and the chronic S. capricornutum (96‐h) assay. The landfill leachates were shown to be highly toxic to both C. dubia and S. capricornutum with an EC50 < 10% and < 15%, respectively. However, Microtox™ was not as sensitive to the leachates. Based on these results, the assays were ranked for their sensitivities to the landfill leachates; C. dubia > S. capricornutum > Microtox™. Chemical analyses showed high concentrations of un‐ionized ammonia and salts in the landfill leachates but low concentrations of heavy metals. The toxicity of the landfill leachates varied between the sites sampled and within each of the landfill sites. A significant relationship was found between the total ammonia content of the leachates and toxicity as determined by the C. dubia and S. capricornutum assays. Although the chemical constituents in Florida MSW landfill leachates may be more dilute, the toxicity of the leachates is equivalent to that from industrial waste landfills. © 2002 Wiley Periodicals, Inc. Environ Toxicol 17: 258–266, 2002; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/tox.10053
Determining toxicity of leachates from Florida municipal solid waste landfills using a battery‐of‐tests approach
10.1002/tox.10053.abs
The toxicity and physicochemical parameters of municipal solid‐waste (MSW) landfill leachates from six sites in north and north‐central Florida, United States, were determined. Landfill leachates are complex mixtures of organic and inorganic constituents. Leachate toxicity was assayed using the acute C. dubia (48‐h) and Microtox™ (15‐min) assays and the chronic S. capricornutum (96‐h) assay. The landfill leachates were shown to be highly toxic to both C. dubia and S. capricornutum with an EC50 < 10% and < 15%, respectively. However, Microtox™ was not as sensitive to the leachates. Based on these results, the assays were ranked for their sensitivities to the landfill leachates; C. dubia > S. capricornutum > Microtox™. Chemical analyses showed high concentrations of un‐ionized ammonia and salts in the landfill leachates but low concentrations of heavy metals. The toxicity of the landfill leachates varied between the sites sampled and within each of the landfill sites. A significant relationship was found between the total ammonia content of the leachates and toxicity as determined by the C. dubia and S. capricornutum assays. Although the chemical constituents in Florida MSW landfill leachates may be more dilute, the toxicity of the leachates is equivalent to that from industrial waste landfills. © 2002 Wiley Periodicals, Inc. Environ Toxicol 17: 258–266, 2002; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/tox.10053
Determining toxicity of leachates from Florida municipal solid waste landfills using a battery‐of‐tests approach
Ward, Marnie L. (Autor:in) / Bitton, Gabriel (Autor:in) / Townsend, Timothy (Autor:in) / Booth, Matthew (Autor:in)
Environmental Toxicology ; 17 ; 258-266
01.01.2002
9 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
PCDD/F/T in Leachates from "Young" and "Old" Municipal Landfills
British Library Online Contents | 2008
|Dynamic Properties of Municipal Solid Waste Landfills from Surface Wave Tests
British Library Conference Proceedings | 1997
|Settlement of municipal solid waste landfills
British Library Conference Proceedings | 1998
|