Residual compressive strength of fire‐damaged mortar after post‐fire‐air‐curing
The effects of cooling regimes and post‐fire‐air‐curing on compressive strength of mortar were investigated. Mortars were made with CEN reference sand, CEM I 42.5 R cement and natural spring water. The sand–cement and water–cement materials' ratios were chosen as 3.0 and 0.50 for all mixtures, respectively. At 28 days, the specimens were heated to maximum temperatures of 400, 600, 800 and 1000°C. Specimens were then allowed to cool in the air, furnace and water. After cooling, the specimens were air‐recured. Compressive strength test was carried out before air‐recuring and after 7 days of air‐recuring. The highest reduction in compressive strength was observed at 1000°C regardless of cooling regime. Gradual cooling regime in air and furnace without post curing showed almost no difference in terms of compressive strength reduction for four elevated temperatures. Shock cooling in water caused significant reduction in compressive strength compared with both gradual cooling regimes without post curing. After air and furnace cooling regimes, 7 days air‐recured specimens showed further reduction in compressive strength for four elevated temperatures. Specimens cooled in water and subjected to 7 days air‐recuring showed significant strength gain approximately 39, 100 and 130% for 400, 600 and 800°C elevated temperature, respectively. Copyright © 2010 John Wiley & Sons, Ltd.
Residual compressive strength of fire‐damaged mortar after post‐fire‐air‐curing
The effects of cooling regimes and post‐fire‐air‐curing on compressive strength of mortar were investigated. Mortars were made with CEN reference sand, CEM I 42.5 R cement and natural spring water. The sand–cement and water–cement materials' ratios were chosen as 3.0 and 0.50 for all mixtures, respectively. At 28 days, the specimens were heated to maximum temperatures of 400, 600, 800 and 1000°C. Specimens were then allowed to cool in the air, furnace and water. After cooling, the specimens were air‐recured. Compressive strength test was carried out before air‐recuring and after 7 days of air‐recuring. The highest reduction in compressive strength was observed at 1000°C regardless of cooling regime. Gradual cooling regime in air and furnace without post curing showed almost no difference in terms of compressive strength reduction for four elevated temperatures. Shock cooling in water caused significant reduction in compressive strength compared with both gradual cooling regimes without post curing. After air and furnace cooling regimes, 7 days air‐recured specimens showed further reduction in compressive strength for four elevated temperatures. Specimens cooled in water and subjected to 7 days air‐recuring showed significant strength gain approximately 39, 100 and 130% for 400, 600 and 800°C elevated temperature, respectively. Copyright © 2010 John Wiley & Sons, Ltd.
Residual compressive strength of fire‐damaged mortar after post‐fire‐air‐curing
Karahan, Okan (Autor:in)
Fire and Materials ; 35 ; 561-567
01.12.2011
7 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
mortar , fire , strength , high temperature , cooling regimes , recuring
Residual compressive strength of fire‐damaged mortar after post‐fire‐air‐curing
Online Contents | 2011
|Residual compressive strength of fire-damaged mortar after post-fire-air-curing
British Library Online Contents | 2011
|Strength and durability recovery of fire-damaged concrete after post-fire-curing
Online Contents | 2001
|Strength and durability recovery of fire-damaged concrete after post-fire-curing
Tema Archiv | 2001
|Strength and durability recovery of fire-damaged concrete after post-fire-curing
British Library Online Contents | 2001
|