Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Evaluation of the seismic performance of a three‐story ordinary moment‐resisting concrete frame
10.1002/eqe.367.abs
This study focuses on the seismic performance of Ordinary Moment‐Resisting Concrete Frames (OMRCF) designed only for gravity loads. For this purpose, a 3‐story OMRCF was designed in compliance with the minimum design requirements in the American Concrete Institute Building Code ACI 318 (1999). This model frame was a regular structure with flexure‐dominated response. A 1/3‐scale 3‐story model was constructed and tested under quasi‐static reversed cyclic lateral loading. The overall behavior of the OMRCF was quite stable without abrupt strength degradation. The measured base shear strength was larger than the design base shear force for seismic zones 1, 2A and 2B calculated using UBC 1997. Moreover, this study used the capacity spectrum method to evaluate the seismic performance of the frame. The capacity curve was obtained from the experimental results for the specimen and the demand curve was established using the earthquake ground motions recorded at various stations with different soil conditions. Evaluation of the test results shows that the 3‐story OMRCF can resist design seismic loads of zones 1, 2A, 2B, 3 and 4 with soil types SA and SB. For soil type SC, the specimen was satisfactory in seismic zones 1, 2A, 2B and 3. For soil type SD, the OMRCF was only satisfactory for seismic zones 1 and 2A. Copyright © 2004 John Wiley & Sons, Ltd.
Evaluation of the seismic performance of a three‐story ordinary moment‐resisting concrete frame
10.1002/eqe.367.abs
This study focuses on the seismic performance of Ordinary Moment‐Resisting Concrete Frames (OMRCF) designed only for gravity loads. For this purpose, a 3‐story OMRCF was designed in compliance with the minimum design requirements in the American Concrete Institute Building Code ACI 318 (1999). This model frame was a regular structure with flexure‐dominated response. A 1/3‐scale 3‐story model was constructed and tested under quasi‐static reversed cyclic lateral loading. The overall behavior of the OMRCF was quite stable without abrupt strength degradation. The measured base shear strength was larger than the design base shear force for seismic zones 1, 2A and 2B calculated using UBC 1997. Moreover, this study used the capacity spectrum method to evaluate the seismic performance of the frame. The capacity curve was obtained from the experimental results for the specimen and the demand curve was established using the earthquake ground motions recorded at various stations with different soil conditions. Evaluation of the test results shows that the 3‐story OMRCF can resist design seismic loads of zones 1, 2A, 2B, 3 and 4 with soil types SA and SB. For soil type SC, the specimen was satisfactory in seismic zones 1, 2A, 2B and 3. For soil type SD, the OMRCF was only satisfactory for seismic zones 1 and 2A. Copyright © 2004 John Wiley & Sons, Ltd.
Evaluation of the seismic performance of a three‐story ordinary moment‐resisting concrete frame
Han, Sang Whan (Autor:in) / Kwon, Oh‐Sung (Autor:in) / Lee, Li‐Hyung (Autor:in)
Earthquake Engineering & Structural Dynamics ; 33 ; 669-685
01.05.2004
17 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Evaluation of the seismic performance of a three-story ordinary moment-resisting concrete frame
Online Contents | 2004
|Evaluation of Seismic Performance of 3 Story Ordinary Moment Resisting Concrete Frames
British Library Conference Proceedings | 2002
|Seismic performance of concrete moment resisting frame buildings in Canada
British Library Online Contents | 2011
|DOAJ | 2015
|