Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Shear and flexural strengthening of deficient flat slabs with post‐installed bolts and CFRP composites bonded through EBR and EBROG
Fiber reinforced polymer (FRP) composites can be efficient for flexural strengthening of flat slabs if debonding of the FRP is postponed. However, with the increase of the flexural capacity, the flat slab becomes more susceptible to punching shear failure. In this context, four flexural or simultaneous flexural and punching shear retrofitting systems are investigated in this study to strengthen a flexure‐deficient flat slab. Externally Bonded Reinforcement on Grooves (EBROG) and externally bonded reinforcement (EBR) methods are used for flexural strengthening in two cases: slabs without punching shear reinforcement and with post‐installed shear bolts as shear reinforcement. According to the results, flexural strengthening of the slab using the EBR and EBROG techniques increased its load capacity by 12% and 21%, respectively. Simultaneous flexural and shear strengthening of the slab using the EBROG technique was the most effective, leading to a 57% enhancement of the load capacity. For specimens whose failure was governed by punching, comparing the results with code predictions showed that Eurocode and ACI (and the respective guide documents fib bulletin 90 and ACI 440.2R) overestimated the capacity of these specimens. In cases where failure was governed by flexure, a simple application of the yield line theory predicted reasonably well the load capacity of the specimens.
Shear and flexural strengthening of deficient flat slabs with post‐installed bolts and CFRP composites bonded through EBR and EBROG
Fiber reinforced polymer (FRP) composites can be efficient for flexural strengthening of flat slabs if debonding of the FRP is postponed. However, with the increase of the flexural capacity, the flat slab becomes more susceptible to punching shear failure. In this context, four flexural or simultaneous flexural and punching shear retrofitting systems are investigated in this study to strengthen a flexure‐deficient flat slab. Externally Bonded Reinforcement on Grooves (EBROG) and externally bonded reinforcement (EBR) methods are used for flexural strengthening in two cases: slabs without punching shear reinforcement and with post‐installed shear bolts as shear reinforcement. According to the results, flexural strengthening of the slab using the EBR and EBROG techniques increased its load capacity by 12% and 21%, respectively. Simultaneous flexural and shear strengthening of the slab using the EBROG technique was the most effective, leading to a 57% enhancement of the load capacity. For specimens whose failure was governed by punching, comparing the results with code predictions showed that Eurocode and ACI (and the respective guide documents fib bulletin 90 and ACI 440.2R) overestimated the capacity of these specimens. In cases where failure was governed by flexure, a simple application of the yield line theory predicted reasonably well the load capacity of the specimens.
Shear and flexural strengthening of deficient flat slabs with post‐installed bolts and CFRP composites bonded through EBR and EBROG
Torabian, Ala (Autor:in) / Isufi, Brisid (Autor:in) / Mostofinejad, Davood (Autor:in) / Pinho Ramos, António (Autor:in)
Structural Concrete ; 22 ; 1147-1164
01.04.2021
18 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
British Library Online Contents | 2018
|Strengthening of Flat Slabs against Punching Shear Using Post-Installed Shear Reinforcement
Online Contents | 2011
|Punching shear strengthening of flat-slabs with CFRP dowels
Online Contents | 2010
|Punching shear strengthening of flat slabs: CFRP and shear reinforcement
BASE | 2015
|Punching shear strengthening of flat slabs: CFRP and shear reinforcement
BASE | 2015
|