Experimental investigation on frequency pulsation effects on a single pass plate heat exchanger performance
This paper investigates combined heat transfer improvement methods. These methods include introducing pulsating flow, adding nanofluids, and manipulating the flow's characteristics in a corrugated plate heat exchanger. Tests are carried out with multi‐walled carbon nanotube (MWCNT), graphene nanoplate (GNP), and a mixture of GNP and MWCNT meeting the requirement of 0.01% nanofluids volume fraction and exposed to pulsation. Results demonstrated that the use of pulsating frequencies from 0 to 30 Hz of GNP‐water, MIX nanofluids–water, and MWCNT–water nanofluids with a constant concentration of 0.01 wt% leads to a significant improvement in heat transfer. Using pure water at frequency f = 0 Hz as a benchmark, the Nusselt number of the mixture nanofluid increases by 15.2%, 27.5%, 40.4%, and 52.8% with the increase of frequency pulsation from 0 to 30 Hz with a slight effect on the pressure‐drop at this low used constant nanofluid concentration = 0.01%. The highest Nusselt number value for GNP‐water nanofluid improved by an amount of 58.3% at the highest frequency compared with pure water at f = 0 Hz.
Experimental investigation on frequency pulsation effects on a single pass plate heat exchanger performance
This paper investigates combined heat transfer improvement methods. These methods include introducing pulsating flow, adding nanofluids, and manipulating the flow's characteristics in a corrugated plate heat exchanger. Tests are carried out with multi‐walled carbon nanotube (MWCNT), graphene nanoplate (GNP), and a mixture of GNP and MWCNT meeting the requirement of 0.01% nanofluids volume fraction and exposed to pulsation. Results demonstrated that the use of pulsating frequencies from 0 to 30 Hz of GNP‐water, MIX nanofluids–water, and MWCNT–water nanofluids with a constant concentration of 0.01 wt% leads to a significant improvement in heat transfer. Using pure water at frequency f = 0 Hz as a benchmark, the Nusselt number of the mixture nanofluid increases by 15.2%, 27.5%, 40.4%, and 52.8% with the increase of frequency pulsation from 0 to 30 Hz with a slight effect on the pressure‐drop at this low used constant nanofluid concentration = 0.01%. The highest Nusselt number value for GNP‐water nanofluid improved by an amount of 58.3% at the highest frequency compared with pure water at f = 0 Hz.
Experimental investigation on frequency pulsation effects on a single pass plate heat exchanger performance
Alikhan, Amina Hmoud (Autor:in) / Maghrebi, Mohammad Javad (Autor:in)
Heat Transfer ; 51 ; 2688-2701
01.05.2022
14 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Thermoplastic kettle auxiliary single-pass oil bath heat exchanger system
Europäisches Patentamt | 2019
|THERMOPLASTIC KETTLE AUXILIARY SINGLE-PASS OIL BATH HEAT EXCHANGER SYSTEM
Europäisches Patentamt | 2019
|Thermoplastic kettle auxiliary single-pass oil bath heat exchanger system
Europäisches Patentamt | 2018
|British Library Online Contents | 2011
|