Performance of a single glazing assembly exposed to enclosure corner fires of increasing severity
10.1002/fam.764.abs
The results of 19 experiments in which a single pane glazing assembly was exposed to enclosure corner fires of increasing severity are presented. The glazing assembly was exposed to a two zone fire enclosure environment, with consistency and repeatability within each set of three experiments conducted at each fire severity level, evident from the enclosure gas temperature profiles. The results presented include heat release rates, enclosure and local gas temperatures, heat flux distributions, glass surface temperatures, shaded glass temperatures thermally induced stains, crack bifurcation patterns and loss of integrity of the glazing assembly. The results and observations obtained are presented in the form of a toolkit for the estimation of the occurrence of cracking and failure of single glazing in enclosure fires. Copyright © 2001 John Wiley & Sons, Ltd.
Performance of a single glazing assembly exposed to enclosure corner fires of increasing severity
10.1002/fam.764.abs
The results of 19 experiments in which a single pane glazing assembly was exposed to enclosure corner fires of increasing severity are presented. The glazing assembly was exposed to a two zone fire enclosure environment, with consistency and repeatability within each set of three experiments conducted at each fire severity level, evident from the enclosure gas temperature profiles. The results presented include heat release rates, enclosure and local gas temperatures, heat flux distributions, glass surface temperatures, shaded glass temperatures thermally induced stains, crack bifurcation patterns and loss of integrity of the glazing assembly. The results and observations obtained are presented in the form of a toolkit for the estimation of the occurrence of cracking and failure of single glazing in enclosure fires. Copyright © 2001 John Wiley & Sons, Ltd.
Performance of a single glazing assembly exposed to enclosure corner fires of increasing severity
Shields, T. J. (Autor:in) / Silcock, G. W. H. (Autor:in) / Flood, M. F. (Autor:in)
Fire and Materials ; 25 ; 123-152
01.07.2001
30 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Performance of a Single Glazing Assembly Exposed to Enclosure Corner Fires of Increasing Severity
Online Contents | 2001
|Performance of a Single Glazing Assembly Exposed to Enclosure Corner Fires of Increasing Severity
British Library Online Contents | 2001
|Behaviour of Double Glazing in Corner Fires
British Library Online Contents | 2005
|Performance of a Single Glazing Assembly Exposed to a Fire in the Centre of an Enclosure