Preliminary Interlaboratory Trial for ISO/DIS 12010: Determination of Short Chain Polychlorinated Alkanes (SCCP) in Water
A first preliminary interlaboratory trial was planned to prepare ISO/DIS 12010: Water quality – determination of short chain polychlorinated alkanes (SCCP) in water – method using GC/MS and electron capture negative ionisation (ECNI). The task was to determine the sum of short chain polychlorinated n‐alkanes with carbon chain lengths of C10–C13 and a chlorine content between 49 and 67% in water by GC‐ECNI‐MS and quantification by multiple linear regression described in ISO/DIS 12010 as the compulsory method. Distributed samples were obtained from a real water extract spiked with a target concentration of 0.4 µg/mL sum of SCCP, i.e. the environmental quality target level according to the Water Framework Directive. The interlaboratory trial included the calibration, a column chromatographic clean up, a concentration step and an integration of chromatographic unresolved humps as well as the quantification with multiple linear regression. Reproducibility standard deviations between 21.5 and 22.9% were achieved by 17 participating laboratories from four countries. The method outlined no significant difference of the results between the standard solution and a real water matrix extract. On the basis of this succeeded preliminary interlaboratory trial the final interlaboratory trial for validation of ISO 12010 was prepared in autumn 2010.
Preliminary Interlaboratory Trial for ISO/DIS 12010: Determination of Short Chain Polychlorinated Alkanes (SCCP) in Water
A first preliminary interlaboratory trial was planned to prepare ISO/DIS 12010: Water quality – determination of short chain polychlorinated alkanes (SCCP) in water – method using GC/MS and electron capture negative ionisation (ECNI). The task was to determine the sum of short chain polychlorinated n‐alkanes with carbon chain lengths of C10–C13 and a chlorine content between 49 and 67% in water by GC‐ECNI‐MS and quantification by multiple linear regression described in ISO/DIS 12010 as the compulsory method. Distributed samples were obtained from a real water extract spiked with a target concentration of 0.4 µg/mL sum of SCCP, i.e. the environmental quality target level according to the Water Framework Directive. The interlaboratory trial included the calibration, a column chromatographic clean up, a concentration step and an integration of chromatographic unresolved humps as well as the quantification with multiple linear regression. Reproducibility standard deviations between 21.5 and 22.9% were achieved by 17 participating laboratories from four countries. The method outlined no significant difference of the results between the standard solution and a real water matrix extract. On the basis of this succeeded preliminary interlaboratory trial the final interlaboratory trial for validation of ISO 12010 was prepared in autumn 2010.
Preliminary Interlaboratory Trial for ISO/DIS 12010: Determination of Short Chain Polychlorinated Alkanes (SCCP) in Water
Geiß, Sabine (Autor:in) / Lettmann, Nicole (Autor:in) / Rey, Aurélien (Autor:in) / Lepper, Herbert (Autor:in) / Körner, Birgit (Autor:in) / Mais, Silvio (Autor:in) / Prey, Theodor (Autor:in) / Hilger, Bettina (Autor:in) / Engelke, Moana (Autor:in) / Lebertz, Stephan (Autor:in)
CLEAN – Soil, Air, Water ; 39 ; 537-542
01.06.2011
6 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Rock Fall Protection System (SCCP) in Critical Highway Locations
British Library Conference Proceedings | 2015
|Bestimmung von kurzkettigen Chlorparaffinen (C10-C13) in Wasserproben nach ISO 12010
BASE | 2015
|Environmental Chemistry and Toxicology of Polychlorinated n-Alkanes
Online Contents | 1998
|