Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Cyclic tests on a hybrid coupled wall utilizing a rocking mechanism
10.1002/eqe.832.abs
A new type of hybrid coupled wall system, consisting of rolled steel coupling beams, reinforced concrete (RC) wall piers, and concrete‐filled tube (CFT) short columns, is introduced. In this new system, the bases of the wall piers are connected to the base beams only through CFT short columns, unlike conventional coupled walls. Yield occurs in the coupling beams and the short columns; hence, in the RC wall piers, only minimum cracking appears. A total of four subassembly specimens, designed to fail in various collapse mechanisms, were cyclically loaded under constant axial force. A benchmark specimen showed ductile behavior with large energy dissipation until fracture occurred in the coupling beam. In the specimen designed to fail in shear in its CFT, substantial axial shortening was observed, but the overall behavior was ductile. Behavior of specimens with small amounts of section steel in the wall panel fringe, or with thin wall panels, also showed ductile behavior, but the strength and energy dissipation were significantly smaller than other two specimens. An analytical model was proposed for a frame analysis program using fiber elements to simulate elastic–plastic behavior of the system. Design methods to prevent shear failure of CFT and RC panels are suggested using the analytical and test results. Copyright © 2008 John Wiley & Sons, Ltd.
Cyclic tests on a hybrid coupled wall utilizing a rocking mechanism
10.1002/eqe.832.abs
A new type of hybrid coupled wall system, consisting of rolled steel coupling beams, reinforced concrete (RC) wall piers, and concrete‐filled tube (CFT) short columns, is introduced. In this new system, the bases of the wall piers are connected to the base beams only through CFT short columns, unlike conventional coupled walls. Yield occurs in the coupling beams and the short columns; hence, in the RC wall piers, only minimum cracking appears. A total of four subassembly specimens, designed to fail in various collapse mechanisms, were cyclically loaded under constant axial force. A benchmark specimen showed ductile behavior with large energy dissipation until fracture occurred in the coupling beam. In the specimen designed to fail in shear in its CFT, substantial axial shortening was observed, but the overall behavior was ductile. Behavior of specimens with small amounts of section steel in the wall panel fringe, or with thin wall panels, also showed ductile behavior, but the strength and energy dissipation were significantly smaller than other two specimens. An analytical model was proposed for a frame analysis program using fiber elements to simulate elastic–plastic behavior of the system. Design methods to prevent shear failure of CFT and RC panels are suggested using the analytical and test results. Copyright © 2008 John Wiley & Sons, Ltd.
Cyclic tests on a hybrid coupled wall utilizing a rocking mechanism
Hitaka, Toko (Autor:in) / Sakino, Kenji (Autor:in)
Earthquake Engineering & Structural Dynamics ; 37 ; 1657-1676
01.11.2008
20 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
hysteresis , CFT , cyclic test , composite , building , coupling beam
Cyclic tests on a hybrid coupled wall utilizing a rocking mechanism
Online Contents | 2008
|Seismic damage mechanism control of rocking wall-frame system
British Library Online Contents | 2011
|Seismic Behaviour of an Innovative Hybrid Coupled Wall System Investigated Through Cyclic Tests
Springer Verlag | 2024
|