Ventilation strategies and indoor particulate matter in a classroom
Particle mass and number concentrations were measured in a mechanically ventilated classroom as part of a study of ventilation strategies for energy conservation. The ventilation system was operated either continuously, intermittently, or shut down during nights while it was on during workdays. It appears that the nighttime ventilation scheme is not important for indoor particle concentrations the following day if fans are operated to give five air exchanges in advance of the workday. The highest concentrations of PM10 were found during and after workdays and were due to human activity in the classroom. The average workday PM10 concentration was 14 μg/m3, well below the WHO guideline values. The number concentration of particles with diameter <0.750 μm was typically between 0.5 × 103 and 3.5 × 103 particle/cm3. These concentrations were largely independent of the occupants. Transient formation of small particles was observed when ventilation was shut down. Then remaining ozone reacted with terpenes emitted by indoor sources and gave up to 8 × 103 particle/cm3 before formation stopped due to lack of ozone. The intermittent ventilation regime was found least favorable for the indoor air quality in the classroom.
Ventilation strategies and indoor particulate matter in a classroom
Particle mass and number concentrations were measured in a mechanically ventilated classroom as part of a study of ventilation strategies for energy conservation. The ventilation system was operated either continuously, intermittently, or shut down during nights while it was on during workdays. It appears that the nighttime ventilation scheme is not important for indoor particle concentrations the following day if fans are operated to give five air exchanges in advance of the workday. The highest concentrations of PM10 were found during and after workdays and were due to human activity in the classroom. The average workday PM10 concentration was 14 μg/m3, well below the WHO guideline values. The number concentration of particles with diameter <0.750 μm was typically between 0.5 × 103 and 3.5 × 103 particle/cm3. These concentrations were largely independent of the occupants. Transient formation of small particles was observed when ventilation was shut down. Then remaining ozone reacted with terpenes emitted by indoor sources and gave up to 8 × 103 particle/cm3 before formation stopped due to lack of ozone. The intermittent ventilation regime was found least favorable for the indoor air quality in the classroom.
Ventilation strategies and indoor particulate matter in a classroom
Fischer, A. (Autor:in) / Ljungström, E. (Autor:in) / Hägerhed Engman, L. (Autor:in) / Langer, S. (Autor:in)
Indoor Air ; 25 ; 168-175
01.04.2015
8 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Classroom Indoor Air Quality vs. Ventilation Rate
British Library Conference Proceedings | 1993
|Classroom Indoor Air Quality vs. Ventilation Rate
British Library Online Contents | 1993
|Successful Indoor Ventilation Strategies
British Library Conference Proceedings | 1993
|