Seismic interaction in linearly connected electrical substation equipment
10.1002/eqe.9.abs
An electrical substation consists of a complex set of equipment items that are interconnected through conductor buses or cables. If the connections are not sufficiently flexible, significant dynamic interaction may occur between the connected equipment items during a seismic excitation. This interaction is believed to be responsible for some of the observed substation equipment damage in recent earthquakes. This paper investigates the interaction between two equipment items connected by a linear spring‐dashpot or spring‐dashpot‐mass element representing a conductor bus. It is found that the interaction between the two equipment items may significantly amplify the response of the higher‐frequency equipment item. The influences of various key parameters on the interaction effect are quantified. Means for reducing the adverse interaction effect are described. Copyright © 2001 John Wiley & Sons, Ltd.
Seismic interaction in linearly connected electrical substation equipment
10.1002/eqe.9.abs
An electrical substation consists of a complex set of equipment items that are interconnected through conductor buses or cables. If the connections are not sufficiently flexible, significant dynamic interaction may occur between the connected equipment items during a seismic excitation. This interaction is believed to be responsible for some of the observed substation equipment damage in recent earthquakes. This paper investigates the interaction between two equipment items connected by a linear spring‐dashpot or spring‐dashpot‐mass element representing a conductor bus. It is found that the interaction between the two equipment items may significantly amplify the response of the higher‐frequency equipment item. The influences of various key parameters on the interaction effect are quantified. Means for reducing the adverse interaction effect are described. Copyright © 2001 John Wiley & Sons, Ltd.
Seismic interaction in linearly connected electrical substation equipment
Der Kiureghian, A. (Autor:in) / Sackman, J. L. (Autor:in) / Hong, K‐J. (Autor:in)
Earthquake Engineering & Structural Dynamics ; 30 ; 327-347
01.03.2001
21 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Seismic interaction in linearly connected electrical substation equipment
Online Contents | 2001
|Seismic Interaction of Interconnected Electrical Substation Equipment
British Library Online Contents | 2000
|Seismic interaction in electrical substation equipment connected by non-linear rigid bus conductors
Online Contents | 2007
|Seismic Interaction between Flexible Conductors and Electrical Substation Equipment
Online Contents | 2005
|