Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Discussion of system intrinsic parameters of tuned mass dampers used for seismic response reduction
Assimilating the structures incorporating tuned mass dampers to 2‐degrees‐of‐freedom mechanical systems, this paper discusses the salient parameters defining the efficiency of these devices when affixed to structures for the purpose of seismic response reduction. Focusing on parameters that are intrinsic to the mechanical systems and independent of ground motions, numerical and analytical expressions are first obtained for the modal damping of the systems. Subsequently, it is proposed that the highest efficiency in terms of modal damping allocation is achieved at tuning that results in modal damping that is in the same proportion as the participation factors for the modes. Further, some properties of the frequencies, tuning, and participation factors are analytically demonstrated. Finally, limited numerical calculations using a spectrum‐compatible accelerogram are offered to support the proposed method for modal damping allocation. Copyright © 2015 John Wiley & Sons, Ltd.
Discussion of system intrinsic parameters of tuned mass dampers used for seismic response reduction
Assimilating the structures incorporating tuned mass dampers to 2‐degrees‐of‐freedom mechanical systems, this paper discusses the salient parameters defining the efficiency of these devices when affixed to structures for the purpose of seismic response reduction. Focusing on parameters that are intrinsic to the mechanical systems and independent of ground motions, numerical and analytical expressions are first obtained for the modal damping of the systems. Subsequently, it is proposed that the highest efficiency in terms of modal damping allocation is achieved at tuning that results in modal damping that is in the same proportion as the participation factors for the modes. Further, some properties of the frequencies, tuning, and participation factors are analytically demonstrated. Finally, limited numerical calculations using a spectrum‐compatible accelerogram are offered to support the proposed method for modal damping allocation. Copyright © 2015 John Wiley & Sons, Ltd.
Discussion of system intrinsic parameters of tuned mass dampers used for seismic response reduction
Miranda, Julio C. (Autor:in)
Structural Control and Health Monitoring ; 23 ; 349-368
01.02.2016
20 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
System intrinsic, damping maximized, tuned mass dampers for seismic applications
Wiley | 2012
|Seismic response reduction of irregular buildings using passive tuned mass dampers
Online Contents | 2000
|Response of discussion “Estimating optimum parameters of tuned mass dampers using harmony search”
Online Contents | 2014
|Seismic Response Control of Structure using Tuned Mass Dampers
British Library Online Contents | 2005
|Response of discussion “Estimating optimum parameters of tuned mass dampers using harmony search”
Online Contents | 2013
|