Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
ClO2 and by‐product persistence in a Drinking Water System
This research evaluated a chlorine gas–solid sodium chlorite chlorine dioxide (ClO2) generation system at the Roanoke County (Va.) Spring Hollow Water Treatment Facility and monitored concentrations of the oxidant and its by‐products within the facility and distribution system. Project objectives were to (1) document changes in ClO2, chlorite ion (ClO2–), and chlorate ion (ClO3–) concentrations throughout the facility and distribution system following raw water ClO2 pretreatment; (2) evaluate ClO2– removal by the postfilter granular activated carbon (GAC) contactors; and (3) determine distribution system ClO2 concentrations associated with odor complaints. The average raw water ClO2 dose was 0.4 mg/L, and overall ClO2– removals by GAC averaged 63% but declined markedly with increasing throughput volume. Distribution system ClO2– concentrations were generally <0.2 mg/L and decreased with increasing distance from the treatment facility; ClO3– never exceeded 0.1 mg/L. ClO2 was measured at low concentrations (0.017–0.17 mg/L) in the distribution system, and a measured concentration of 0.03 mg/L was found at the home of one customer who complained of odors.
ClO2 and by‐product persistence in a Drinking Water System
This research evaluated a chlorine gas–solid sodium chlorite chlorine dioxide (ClO2) generation system at the Roanoke County (Va.) Spring Hollow Water Treatment Facility and monitored concentrations of the oxidant and its by‐products within the facility and distribution system. Project objectives were to (1) document changes in ClO2, chlorite ion (ClO2–), and chlorate ion (ClO3–) concentrations throughout the facility and distribution system following raw water ClO2 pretreatment; (2) evaluate ClO2– removal by the postfilter granular activated carbon (GAC) contactors; and (3) determine distribution system ClO2 concentrations associated with odor complaints. The average raw water ClO2 dose was 0.4 mg/L, and overall ClO2– removals by GAC averaged 63% but declined markedly with increasing throughput volume. Distribution system ClO2– concentrations were generally <0.2 mg/L and decreased with increasing distance from the treatment facility; ClO3– never exceeded 0.1 mg/L. ClO2 was measured at low concentrations (0.017–0.17 mg/L) in the distribution system, and a measured concentration of 0.03 mg/L was found at the home of one customer who complained of odors.
ClO2 and by‐product persistence in a Drinking Water System
Hoehn, Robert C. (Autor:in) / Ellenberger, Christine S. (Autor:in) / Gallagher, Daniel L. (Autor:in) / Wiseman, Eurman (“Toby”) V. Jr. (Autor:in) / Benninger, Robert W. (Autor:in) / Rosenblatt, Aaron (Autor:in)
Journal ‐ American Water Works Association ; 95 ; 141-150
01.04.2003
10 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Comparison between H2O2-W and ClO2 disinfection of drinking water
Online Contents | 1995
|ClO2 on demand disinfectant sponge or wipe and method of making
Europäisches Patentamt | 2019
|Susceptibility of stainless steel alloys to crevice corrosion in ClO2 bleach plants
British Library Online Contents | 2004
|Crayfish as Bioindicators for Monitoring ClO2: A Case Study from a Brewery Water Treatment Facility
DOAJ | 2019
|Persistence of Pseudomonas aeruginosa in drinking-water biofilms on elastomeric material
Online Contents | 2009
|