Study on seismic performance of a super‐tall steel–concrete hybrid structure
Many steel–concrete hybrid buildings have been built in China. The seismic performance of such hybrid system is much more complicated than that of steel structure or reinforced concrete (RC) structure. A steel–concrete hybrid frame‐tube super‐tall building structure with new type of shear walls to be built in a district of seismic intensity 8 in China was studied for its structural complexity and irregularity. Both model test and numerical simulation were applied to obtain the detailed knowledge of seismic performance for this structure. First, a 1/30 scaled model structure was tested on the shaking table under different levels of earthquakes. The failure process and mechanism of the model structure are presented here. Nonlinear time‐history analysis of the prototype structure was then conducted by using the software PERFORM‐3D. The dynamic characteristics, inter‐story drift ratios and energy dissipation conditions are introduced. On the basis of the comparison between the deformation demand and capacity of main structural components at individual performance level under different earthquake level, the seismic performance at the member level was also evaluated. Despite the structural complexity and code‐exceeding height, both experimental and analytical results indicate that the overall seismic performance of the structure meet the requirements of the Chinese design code. Copyright © 2012 John Wiley & Sons, Ltd.
Study on seismic performance of a super‐tall steel–concrete hybrid structure
Many steel–concrete hybrid buildings have been built in China. The seismic performance of such hybrid system is much more complicated than that of steel structure or reinforced concrete (RC) structure. A steel–concrete hybrid frame‐tube super‐tall building structure with new type of shear walls to be built in a district of seismic intensity 8 in China was studied for its structural complexity and irregularity. Both model test and numerical simulation were applied to obtain the detailed knowledge of seismic performance for this structure. First, a 1/30 scaled model structure was tested on the shaking table under different levels of earthquakes. The failure process and mechanism of the model structure are presented here. Nonlinear time‐history analysis of the prototype structure was then conducted by using the software PERFORM‐3D. The dynamic characteristics, inter‐story drift ratios and energy dissipation conditions are introduced. On the basis of the comparison between the deformation demand and capacity of main structural components at individual performance level under different earthquake level, the seismic performance at the member level was also evaluated. Despite the structural complexity and code‐exceeding height, both experimental and analytical results indicate that the overall seismic performance of the structure meet the requirements of the Chinese design code. Copyright © 2012 John Wiley & Sons, Ltd.
Study on seismic performance of a super‐tall steel–concrete hybrid structure
Jiang, Huanjun (Autor:in) / Fu, Bo (Autor:in) / Liu, Laoer (Autor:in) / Yin, Xiaowei (Autor:in)
The Structural Design of Tall and Special Buildings ; 23 ; 334-349
10.04.2014
16 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Seismic Performance Evaluation of a Super-Tall Building Structure
Trans Tech Publications | 2012
|Seismic Performance Evaluation of a Super-Tall Building Structure
Tema Archiv | 2012
|Seismic Performance Evaluation of a Super-Tall Building Structure
British Library Conference Proceedings | 2012
|