Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Strengthening of moment‐resisting frame structures against near‐fault ground motion effects
10.1002/eqe.370.abs
Near‐fault ground motions with forward directivity are characterized by a large pulse. This pulse‐like motion may cause a highly non‐uniform distribution of story ductility demands for code‐compliant frame structures, with maximum demands that may considerably exceed the level of code expectations. Strengthening techniques for multi‐story frame structures are explored with the objective of reducing maximum drift demands. One option is to modify the code‐based SRSS distribution of story shear strength over the height by strengthening of the lower stories of the frame. The modified distribution reduces the maximum story ductility demand, particularly for weak and flexible structures. However, this strengthening technique is less effective for stiff structures, and is almost ineffective in cases in which the maximum demand occurs in the upper stories, i.e. strong and flexible structures. As an alternative, the benefits of strengthening frames with elastic and inelastic walls are evaluated. The effects of adding walls that are either fixed or hinged at the base are investigated. It is demonstrated that strengthening with hinged walls is very effective in reducing drift demands for structures with a wide range of periods and at various performance levels. Wall inelastic behavior only slightly reduces the benefits of strengthening with hinged walls.Copyright © 2004 John Wiley & Sons, Ltd.
Strengthening of moment‐resisting frame structures against near‐fault ground motion effects
10.1002/eqe.370.abs
Near‐fault ground motions with forward directivity are characterized by a large pulse. This pulse‐like motion may cause a highly non‐uniform distribution of story ductility demands for code‐compliant frame structures, with maximum demands that may considerably exceed the level of code expectations. Strengthening techniques for multi‐story frame structures are explored with the objective of reducing maximum drift demands. One option is to modify the code‐based SRSS distribution of story shear strength over the height by strengthening of the lower stories of the frame. The modified distribution reduces the maximum story ductility demand, particularly for weak and flexible structures. However, this strengthening technique is less effective for stiff structures, and is almost ineffective in cases in which the maximum demand occurs in the upper stories, i.e. strong and flexible structures. As an alternative, the benefits of strengthening frames with elastic and inelastic walls are evaluated. The effects of adding walls that are either fixed or hinged at the base are investigated. It is demonstrated that strengthening with hinged walls is very effective in reducing drift demands for structures with a wide range of periods and at various performance levels. Wall inelastic behavior only slightly reduces the benefits of strengthening with hinged walls.Copyright © 2004 John Wiley & Sons, Ltd.
Strengthening of moment‐resisting frame structures against near‐fault ground motion effects
Alavi, Babak (Autor:in) / Krawinkler, Helmut (Autor:in)
Earthquake Engineering & Structural Dynamics ; 33 ; 707-722
01.05.2004
16 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Strengthening of moment-resisting frame structures against near-fault ground motion effects
Online Contents | 2004
|Behavior of moment-resisting frame structures subjected to near-fault ground motions
Online Contents | 2004
|Strengthening of moment-resisting frame using cable–cylinder bracing
SAGE Publications | 2016
|Strengthening of moment-resisting frame using cable-cylinder bracing
Online Contents | 2016
|