Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Experimental exergy and entransy analyses on designed and fabricated crossflow heat exchanger
A crossflow heat exchanger (CFHEx) is designed and fabricated in a workshop. For designing this heat exchanger (HEx), the number of passes, frontal areas, HEx volumes, heat transfer areas, free‐flow areas, ratios of minimum free‐flow area to frontal area, densities, mass flow rates of flowing fluids, maximum/minimum heat capacities, heat capacity ratio, outlet temperatures of hot/cold fluids, average temperatures, mass velocities, Reynolds numbers, and convective heat transfer coefficients are evaluated by considering Colburn/friction factors. After fabrication of the HEx, effectiveness, exergy destruction, entransy dissipation, entransy dissipation‐based thermal resistance, entransy dissipation number, and entransy effectiveness for hot/cold fluids sides are found at different flow rates and inlet temperatures of fluids. By experimental results, optimum operating conditions are found, which gives maximum effectiveness and entransy effectiveness but minimum rates of exergy destruction, entransy dissipation, entransy dissipation‐based thermal resistance, and entransy dissipation number for the fabricated CFHEx. This study is concluded as follows: minimum exergy destruction and entransy dissipation rates (ie, 3.061 kJ/s·K and 1125.44 kJ·K/s, respectively) are found during experiment 2. Maximum entransy effectiveness of hot/cold fluids (ie, 0.689/0.21) is achieved in experiment 1. Moderate values of entransy dissipation number (ie, 4.689), entransy dissipation‐based thermal resistance (ie, 0.04 s·K/J), exergy destruction (ie, 3.845 kJ/s·K), and entransy dissipation (ie, 1374.04 kJ·K/s) rates are found during experiment 1. Maximum effectiveness (ie, 0.4) for the fabricated HEx is also obtained through experiment 1. After comparative analyses, it is found that experiment 1 provides optimum results, which shows the best performance of the fabricated HEx.
Experimental exergy and entransy analyses on designed and fabricated crossflow heat exchanger
A crossflow heat exchanger (CFHEx) is designed and fabricated in a workshop. For designing this heat exchanger (HEx), the number of passes, frontal areas, HEx volumes, heat transfer areas, free‐flow areas, ratios of minimum free‐flow area to frontal area, densities, mass flow rates of flowing fluids, maximum/minimum heat capacities, heat capacity ratio, outlet temperatures of hot/cold fluids, average temperatures, mass velocities, Reynolds numbers, and convective heat transfer coefficients are evaluated by considering Colburn/friction factors. After fabrication of the HEx, effectiveness, exergy destruction, entransy dissipation, entransy dissipation‐based thermal resistance, entransy dissipation number, and entransy effectiveness for hot/cold fluids sides are found at different flow rates and inlet temperatures of fluids. By experimental results, optimum operating conditions are found, which gives maximum effectiveness and entransy effectiveness but minimum rates of exergy destruction, entransy dissipation, entransy dissipation‐based thermal resistance, and entransy dissipation number for the fabricated CFHEx. This study is concluded as follows: minimum exergy destruction and entransy dissipation rates (ie, 3.061 kJ/s·K and 1125.44 kJ·K/s, respectively) are found during experiment 2. Maximum entransy effectiveness of hot/cold fluids (ie, 0.689/0.21) is achieved in experiment 1. Moderate values of entransy dissipation number (ie, 4.689), entransy dissipation‐based thermal resistance (ie, 0.04 s·K/J), exergy destruction (ie, 3.845 kJ/s·K), and entransy dissipation (ie, 1374.04 kJ·K/s) rates are found during experiment 1. Maximum effectiveness (ie, 0.4) for the fabricated HEx is also obtained through experiment 1. After comparative analyses, it is found that experiment 1 provides optimum results, which shows the best performance of the fabricated HEx.
Experimental exergy and entransy analyses on designed and fabricated crossflow heat exchanger
Geete, Ankur (Autor:in) / Mahajan, Ajinkya (Autor:in) / Shinde, Ankit (Autor:in) / Modak, Deepak (Autor:in)
Heat Transfer ; 50 ; 1758-1775
01.03.2021
18 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
Entropy, Exergy and Entransy Analyses on Fabricated Shell and Spiral Tube Heat Exchanger
Springer Verlag | 2021
|Entropy, Exergy and Entransy Analyses on Fabricated Shell and Spiral Tube Heat Exchanger
Springer Verlag | 2021
|Exergy and entransy analyses in air-conditioning system part 1—Similarity and distinction
Online Contents | 2016
|Experimental study of air source heat pump water heater: Energy, exergy, and entransy analysis
DOAJ | 2025
|Exergy and entransy analyses in air-conditioning system part 2—Humid air handling process
Online Contents | 2017
|