Analysis of a premature failure of welded AISI 316L stainless steel pipes originated by microbial induced corrosion
Analysis of a premature failure of welded AISI 316L stainless steel pipes originated by microbial induced corrosion
Analysis of a premature failure of welded AISI 316L stainless steel pipes originated by microbial induced corrosion
Otero, E. (author) / Bastidas, J. M. (author) / Lopez, V. (author)
WERKSTOFFE UND KORROSION -WEINHEIM- ; 48 ; 447-454
1997-01-01
8 pages
Article (Journal)
English
DDC:
620.11223
© Metadata Copyright the British Library Board and other contributors. All rights reserved.
Passivation of welded AISI 316L stainless steel
British Library Online Contents | 2008
|Metallurgical investigation of premature failures for 316L austenitic stainless steel pipes
BASE | 2018
|Evaluation of AISI 316L stainless steel welded plates in heavy petroleum environment
British Library Online Contents | 2009
|Assessment of intergranular corrosion in AISI Type 316L stainless steel weldments
British Library Online Contents | 2002
|