Tension Capacity of Staggered Bolted Connections in Cold-Reduced Steel Sheets
This paper examines the assumption implicit in Cochrane’s formula that stresses are uniformly distributed across the net section of a staggered bolted connection. The assumption was found to be overoptimistic for connections in steel having low ductility, leading to unconservative estimates for the tension capacity if the in-plane shear lag is not accounted for. The reduction factor of 0.9 specified in the North American specification for cold-formed steel structures partially, but not wholly, addresses the problems inherent in the code equations. This paper points out that the simplification of Cochrane’s original formula into the standard formula used in steel design codes worldwide can lead to additional design capacity that may not be justified. It proposes an equation that accounts for the in-plane shear lag and incorporates Cochrane’s original formula for determining the net section area. The proposed equation is demonstrated through laboratory tests on 74 staggered bolted connection specimens in 1.5 mm and 3.0 mm G450 sheet steel to be more accurate and consistent than the code equations in predicting the net section tension capacity.
Tension Capacity of Staggered Bolted Connections in Cold-Reduced Steel Sheets
This paper examines the assumption implicit in Cochrane’s formula that stresses are uniformly distributed across the net section of a staggered bolted connection. The assumption was found to be overoptimistic for connections in steel having low ductility, leading to unconservative estimates for the tension capacity if the in-plane shear lag is not accounted for. The reduction factor of 0.9 specified in the North American specification for cold-formed steel structures partially, but not wholly, addresses the problems inherent in the code equations. This paper points out that the simplification of Cochrane’s original formula into the standard formula used in steel design codes worldwide can lead to additional design capacity that may not be justified. It proposes an equation that accounts for the in-plane shear lag and incorporates Cochrane’s original formula for determining the net section area. The proposed equation is demonstrated through laboratory tests on 74 staggered bolted connection specimens in 1.5 mm and 3.0 mm G450 sheet steel to be more accurate and consistent than the code equations in predicting the net section tension capacity.
Tension Capacity of Staggered Bolted Connections in Cold-Reduced Steel Sheets
Teh, Lip H. (author) / Clements, Drew D. A. (author)
Journal of Structural Engineering ; 138 ; 769-776
2011-09-26
82012-01-01 pages
Article (Journal)
Electronic Resource
English
Tension Capacity of Staggered Bolted Connections in Cold-Reduced Steel Sheets
Online Contents | 2012
|Tension Capacity of Staggered Bolted Connections in Cold-Reduced Steel Sheets
British Library Online Contents | 2012
|Net Section Tension Capacity of Bolted Connections in Cold-Reduced Steel Sheets
British Library Online Contents | 2012
|Net Section Tension Capacity of Bolted Connections in Cold-Reduced Steel Sheets
Online Contents | 2012
|Block Shear Capacity of Bolted Connections in Cold-Reduced Steel Sheets
Online Contents | 2012
|