A platform for research: civil engineering, architecture and urbanism
Chemico-Osmotic Coefficients of Geosynthetic Clay Liners under Different Confinement Conditions
Chemico-osmotic diffusion tests have been widely used to determine the chemico-osmotic coefficient (ω) of soils and geosynthetic clay liners (GCLs). A modified device for chemico-osmotic testing has been developed, which offers the option to confine the specimen by a load cell to monitor the total stress, besides the commonly adopted approach (confinement by a blocked piston). Being the strain conditions slightly different between the two approaches (i.e., small-strain versus no-strain), comparative chemico-osmotic tests have been performed. A dense prehydrated GCL and a 20 mM KCl as source solution were used. Under the no-strain condition ω was 0.33. Under the small-strain condition ω was 0.31, and the total vertical stress changed from 59 kPa in equilibrium with deionized water to 22 kPa in equilibrium with 20 mM KCl. Therefore, very close osmotic coefficients were obtained, with the advantage of monitoring the vertical stress during the test when using the load cell.
Chemico-Osmotic Coefficients of Geosynthetic Clay Liners under Different Confinement Conditions
Chemico-osmotic diffusion tests have been widely used to determine the chemico-osmotic coefficient (ω) of soils and geosynthetic clay liners (GCLs). A modified device for chemico-osmotic testing has been developed, which offers the option to confine the specimen by a load cell to monitor the total stress, besides the commonly adopted approach (confinement by a blocked piston). Being the strain conditions slightly different between the two approaches (i.e., small-strain versus no-strain), comparative chemico-osmotic tests have been performed. A dense prehydrated GCL and a 20 mM KCl as source solution were used. Under the no-strain condition ω was 0.33. Under the small-strain condition ω was 0.31, and the total vertical stress changed from 59 kPa in equilibrium with deionized water to 22 kPa in equilibrium with 20 mM KCl. Therefore, very close osmotic coefficients were obtained, with the advantage of monitoring the vertical stress during the test when using the load cell.
Chemico-Osmotic Coefficients of Geosynthetic Clay Liners under Different Confinement Conditions
Mazzieri, Francesco (author) / Bernardo, D. (author)
Geo-Congress 2023 ; 2023 ; Los Angeles, California
Geo-Congress 2023 ; 116-126
2023-03-23
Conference paper
Electronic Resource
English
Chemico-Osmotic Coefficients of Geosynthetic Clay Liners under Different Confinement Conditions
British Library Conference Proceedings | 2023
|Chemico-Osmotic Efficiency of a Geosynthetic Clay Liner
Online Contents | 2002
|Chemico-Osmotic Efficiency of a Geosynthetic Clay Liner
British Library Online Contents | 2002
|British Library Conference Proceedings | 1996