Ground Displacements and Pulling Forces of Pipe-Swallowing in Well-Graded Sand
Pipe bursting is a trenchless replacement method for existing pipe with less surface disturbance than traditional open-cut construction. In some instances, potential ground movements caused by pipe bursting construction may lead to damage of surrounding structures. Pipe-swallowing is a pipe replacement technique that involves the replacement of a buried pipe with minimal surface disturbances. An experiment was performed in a 3.0 × 1.8 × 1.5 m test box to quantify ground movements during pipe-swallowing. An existing 300 mm diameter high-density polyethylene (HDPE) pipe was buried 1 m below the ground surface and replaced with a 300 mm diameter HDPE pipe. Pulling forces and the three-dimensional surface displacements associated with the pipe-swallowing operation were investigated. It is concluded that the pulling forces associated with pipe-swallowing were higher than with pipe-bursting, and almost no vertical or transverse displacements of the ground surface were observed during the tests. These data can be used as a database for specialists applying their operation in the field and related research into ground disturbance during pipe-swallowing.
Ground Displacements and Pulling Forces of Pipe-Swallowing in Well-Graded Sand
Pipe bursting is a trenchless replacement method for existing pipe with less surface disturbance than traditional open-cut construction. In some instances, potential ground movements caused by pipe bursting construction may lead to damage of surrounding structures. Pipe-swallowing is a pipe replacement technique that involves the replacement of a buried pipe with minimal surface disturbances. An experiment was performed in a 3.0 × 1.8 × 1.5 m test box to quantify ground movements during pipe-swallowing. An existing 300 mm diameter high-density polyethylene (HDPE) pipe was buried 1 m below the ground surface and replaced with a 300 mm diameter HDPE pipe. Pulling forces and the three-dimensional surface displacements associated with the pipe-swallowing operation were investigated. It is concluded that the pulling forces associated with pipe-swallowing were higher than with pipe-bursting, and almost no vertical or transverse displacements of the ground surface were observed during the tests. These data can be used as a database for specialists applying their operation in the field and related research into ground disturbance during pipe-swallowing.
Ground Displacements and Pulling Forces of Pipe-Swallowing in Well-Graded Sand
Yan, Xuefeng (author) / Ariaratnam, Samuel T. (author) / Ma, Baosong (author) / Zeng, Cong (author)
Pipelines 2020 ; 2020 ; San Antonio, Texas (Conference Held Virtually)
Pipelines 2020 ; 420-426
2020-08-06
Conference paper
Electronic Resource
English
Ground Displacements from a Pipe-Bursting Experiment in Well-Graded Sand and Gravel
Online Contents | 2009
|Ground Displacements from a Pipe-Bursting Experiment in Well-Graded Sand and Gravel
British Library Online Contents | 2009
|Ground displacements caused by pipe splitting
British Library Conference Proceedings | 2001
|