A platform for research: civil engineering, architecture and urbanism
Analyzing Unsatisfactory Fire Sprinkler Performance
Automatic fire sprinkler systems are often considered the most significant component of a building fire protection strategy. When properly designed, installed, tested and maintained, they can control a fire and significantly reduce deaths, injuries, and property damage. However, mistakes during the design/installation phase and during periodic inspection, testing and maintenance activities can have a profound impact on the effectiveness of automatic fire sprinkler systems. This paper explores recent automatic fire sprinkler system failure data to identify current causes of unsatisfactory system performance, highlighting many specific root causes through the examination of past fire loss data across a broad range of occupancies. In addition, specific examples of recent fires where the automatic fire sprinkler system performed in an unsatisfactory manor are presented. By understanding the most common root causes and studying past examples, a forensic engineer can be better prepared to investigate and analyze future failures and losses.
Analyzing Unsatisfactory Fire Sprinkler Performance
Automatic fire sprinkler systems are often considered the most significant component of a building fire protection strategy. When properly designed, installed, tested and maintained, they can control a fire and significantly reduce deaths, injuries, and property damage. However, mistakes during the design/installation phase and during periodic inspection, testing and maintenance activities can have a profound impact on the effectiveness of automatic fire sprinkler systems. This paper explores recent automatic fire sprinkler system failure data to identify current causes of unsatisfactory system performance, highlighting many specific root causes through the examination of past fire loss data across a broad range of occupancies. In addition, specific examples of recent fires where the automatic fire sprinkler system performed in an unsatisfactory manor are presented. By understanding the most common root causes and studying past examples, a forensic engineer can be better prepared to investigate and analyze future failures and losses.
Analyzing Unsatisfactory Fire Sprinkler Performance
Blum, A. F. (author) / Long, Jr., R. T. (author) / Wu, N. P. (author) / Dillon, S. E. (author)
Sixth Congress on Forensic Engineering ; 2012 ; San Francisco, California, United States
Forensic Engineering 2012 ; 547-555
2012-11-13
Conference paper
Electronic Resource
English
Why unsatisfactory sprinkler fires?
Engineering Index Backfile | 1949
|Fire Protection: Smoke Control Requirements Is high-rise sprinkler performance unsatisfactory?
British Library Online Contents | 2004
Automatic Fire Sprinkler System Performance
British Library Online Contents | 1994
Sprinkler Performance in Residential Fire Tests