A platform for research: civil engineering, architecture and urbanism
Shake Table Test of Full-Size Wooden Houses versus Wall Test Result: Comparison of Load-Deformation Relationship
The design procedure considered in the Japanese code for low-rise timber houses (two or fewer stories), is through a wall volume method. The wall volume method entails calculating the shear capacity of each wall through addition of shear walls. However, past earthquake damages highlighted the vulnerability of light timber structures and warrant detailed evaluations to assess the design practice. In this study, load-deformation () relations of the wall are combined to estimate the story shear drift. The general calculation of the amount of walls as a design method for a house is very simple. Buildings damaged in recent earthquakes have become of a concern to decision makers, owners, and designers. To validate the wall volume method, 21 full-scale shake table tests are compared with static wall test results. From the analytical and experimental studies, the short-term allowable shear strength in design with the full-scale experiment is about 2.25 times the standard method and about 2.0 times the quality verification method. Regarding the relationship, the rigidity and maximum load obtained from the experimental tests are 1.2 and 1.3 times larger than the addition, respectively. This paper has highlighted also influences of nonstructural members on the overall response of the structures.
Shake Table Test of Full-Size Wooden Houses versus Wall Test Result: Comparison of Load-Deformation Relationship
The design procedure considered in the Japanese code for low-rise timber houses (two or fewer stories), is through a wall volume method. The wall volume method entails calculating the shear capacity of each wall through addition of shear walls. However, past earthquake damages highlighted the vulnerability of light timber structures and warrant detailed evaluations to assess the design practice. In this study, load-deformation () relations of the wall are combined to estimate the story shear drift. The general calculation of the amount of walls as a design method for a house is very simple. Buildings damaged in recent earthquakes have become of a concern to decision makers, owners, and designers. To validate the wall volume method, 21 full-scale shake table tests are compared with static wall test results. From the analytical and experimental studies, the short-term allowable shear strength in design with the full-scale experiment is about 2.25 times the standard method and about 2.0 times the quality verification method. Regarding the relationship, the rigidity and maximum load obtained from the experimental tests are 1.2 and 1.3 times larger than the addition, respectively. This paper has highlighted also influences of nonstructural members on the overall response of the structures.
Shake Table Test of Full-Size Wooden Houses versus Wall Test Result: Comparison of Load-Deformation Relationship
Isoda, Hiroshi (author) / Matsuda, Masahiro (author) / Tesfamariam, Solomon (author) / Tamori, Shinichiro (author)
2021-06-28
Article (Journal)
Electronic Resource
Unknown
Full-Scale Shaking Table Test of Two Story Wooden Dwelling Houses
British Library Conference Proceedings | 1998
|Shake Table Test on Rammed Earth Wall Panels
British Library Conference Proceedings | 2010
|Twin Shake Tables Subject Wooden House to Seismic Test
ASCE | 2016
|Shake-Table Test of a Full-Scale 7-Story Building Slice. Phase I: Rectangular Wall
Online Contents | 2011
|