A platform for research: civil engineering, architecture and urbanism
Seismic Damage Assessment and Shaking-Table Test Validation of Midrise Cold-Formed Steel Composite Shear Wall Buildings
This paper proposes damage index–based limit-state criteria for seismic design of midrise cold-formed steel (CFS) buildings instead of the drift-based ones, and the Park-Ang damage model was used to calculate the damage indexes. Two 5-story CFS buildings with different wall configurations were tested, and a test-validated numerical model was developed. An incremental dynamic analysis was conducted on a typical midrise CFS building to obtain the degradation parameter β of different CFS walls. The damage indexes computed from numerical analyses were compared with the damage indexes estimated from test observations and the proposed damage index–based limit-state criteria. The results showed that the calculated degradation parameter as well as the proposed damage index–based limit-state criteria are effective for seismic damage assessment and damage level classification of midrise CFS buildings according to the validations by shaking-table tests on two CFS buildings. The Park-Ang damage index used in this paper and the proposed limit-state criteria could be used for performance-based seismic design of midrise CFS buildings.
Seismic Damage Assessment and Shaking-Table Test Validation of Midrise Cold-Formed Steel Composite Shear Wall Buildings
This paper proposes damage index–based limit-state criteria for seismic design of midrise cold-formed steel (CFS) buildings instead of the drift-based ones, and the Park-Ang damage model was used to calculate the damage indexes. Two 5-story CFS buildings with different wall configurations were tested, and a test-validated numerical model was developed. An incremental dynamic analysis was conducted on a typical midrise CFS building to obtain the degradation parameter β of different CFS walls. The damage indexes computed from numerical analyses were compared with the damage indexes estimated from test observations and the proposed damage index–based limit-state criteria. The results showed that the calculated degradation parameter as well as the proposed damage index–based limit-state criteria are effective for seismic damage assessment and damage level classification of midrise CFS buildings according to the validations by shaking-table tests on two CFS buildings. The Park-Ang damage index used in this paper and the proposed limit-state criteria could be used for performance-based seismic design of midrise CFS buildings.
Seismic Damage Assessment and Shaking-Table Test Validation of Midrise Cold-Formed Steel Composite Shear Wall Buildings
J. Struct. Eng.
Jiang, Liqiang (author) / Yu, Kai (author) / Ye, Jihong (author) / Hu, Yi (author) / Jiang, Lizhong (author)
2022-08-01
Article (Journal)
Electronic Resource
English
Performance-Based Seismic Design of Midrise Woodframe Buildings
Online Contents | 2013
|Midply Truss Wall System: High-Performance Shear Wall for Midrise Wood-Frame Buildings
British Library Online Contents | 2012
|