A platform for research: civil engineering, architecture and urbanism
Internal Damping Ratio of Ultrahigh-Performance Fiber-Reinforced Concrete Considering the Effect of Fiber Content and Damage Evolution
This paper reports the characterization of internal damping ratio () and factor of ultrahigh-performance fiber-reinforced concrete (UHPFRC) using acoustic tests for undamaged and damaged samples excited by an impact. Ratio is a nondimensional parameter that measures the material capacity to dissipate vibration, and the factor is physically interpreted as inverse attenuation, measuring the undamped characteristics of an oscillator. A servohydraulic testing machine was used for straining the samples cyclically, and at the end of each cycle the acoustic tests were made to measure and . Furthermore, scanning electron microscopy (SEM) was performed in samples extracted from the damaged specimens. From results, undamaged samples presented average around 0.35% with maximum and minimum values of 0.50% and 0.15%, respectively. The analysis of damaged samples showed that the internal damping gave a small variation in the first two load cycles and achieved 0.8% after the peak stress. Low values of found in the present study suggest that UHPFRC structures are more susceptible to excessive vibrations than normal-strength concrete structures. Moreover, SEM images showed damage mechanisms that are the probable reasons for the increase of after severe loading.
Internal Damping Ratio of Ultrahigh-Performance Fiber-Reinforced Concrete Considering the Effect of Fiber Content and Damage Evolution
This paper reports the characterization of internal damping ratio () and factor of ultrahigh-performance fiber-reinforced concrete (UHPFRC) using acoustic tests for undamaged and damaged samples excited by an impact. Ratio is a nondimensional parameter that measures the material capacity to dissipate vibration, and the factor is physically interpreted as inverse attenuation, measuring the undamped characteristics of an oscillator. A servohydraulic testing machine was used for straining the samples cyclically, and at the end of each cycle the acoustic tests were made to measure and . Furthermore, scanning electron microscopy (SEM) was performed in samples extracted from the damaged specimens. From results, undamaged samples presented average around 0.35% with maximum and minimum values of 0.50% and 0.15%, respectively. The analysis of damaged samples showed that the internal damping gave a small variation in the first two load cycles and achieved 0.8% after the peak stress. Low values of found in the present study suggest that UHPFRC structures are more susceptible to excessive vibrations than normal-strength concrete structures. Moreover, SEM images showed damage mechanisms that are the probable reasons for the increase of after severe loading.
Internal Damping Ratio of Ultrahigh-Performance Fiber-Reinforced Concrete Considering the Effect of Fiber Content and Damage Evolution
Gidrão, Gustavo de Miranda Saleme (author) / Krahl, Pablo Augusto (author) / Carrazedo, Ricardo (author)
2020-09-21
Article (Journal)
Electronic Resource
Unknown
Internal Damping Ratio of Normal- and High-Strength Concrete Considering Mechanical Damage Evolution
DOAJ | 2024
|Shrinkage of Fiber-Reinforced Ultrahigh Strength Concrete
British Library Online Contents | 2012
|Shrinkage of Fiber-Reinforced Ultrahigh Strength Concrete
Online Contents | 2012
|