A platform for research: civil engineering, architecture and urbanism
Negative Stiffness Device for Seismic Protection of Structures: Shake Table Testing of a Seismically Isolated Structure
The concept of apparent weakening by adding true negative stiffness to a structure has been previously introduced by the authors in order to reduce simultaneous drifts, accelerations, and displacements in a structure without yielding or permanent deformation in the main system. A novel negative stiffness device (NSD) that generates true negative stiffness has been developed, built, and tested and has been previously described by the authors in terms of operation and analytical and numerical modeling. This paper presents results that represent proof-of-concept for weakening with the use of the NSD based on the shake table testing of a 3-story seismically isolated structure, equipped with these devices complemented by viscous dampers. The NSD is shown to have a significant effect on the superstructure response by reducing floor accelerations, story drift, and the base shear and upon the addition of dampers, also results in a reduction in isolator displacements. Moreover, this paper provides validation of the analytical models that were previously developed by comparison of analytical and experimental results.
Negative Stiffness Device for Seismic Protection of Structures: Shake Table Testing of a Seismically Isolated Structure
The concept of apparent weakening by adding true negative stiffness to a structure has been previously introduced by the authors in order to reduce simultaneous drifts, accelerations, and displacements in a structure without yielding or permanent deformation in the main system. A novel negative stiffness device (NSD) that generates true negative stiffness has been developed, built, and tested and has been previously described by the authors in terms of operation and analytical and numerical modeling. This paper presents results that represent proof-of-concept for weakening with the use of the NSD based on the shake table testing of a 3-story seismically isolated structure, equipped with these devices complemented by viscous dampers. The NSD is shown to have a significant effect on the superstructure response by reducing floor accelerations, story drift, and the base shear and upon the addition of dampers, also results in a reduction in isolator displacements. Moreover, this paper provides validation of the analytical models that were previously developed by comparison of analytical and experimental results.
Negative Stiffness Device for Seismic Protection of Structures: Shake Table Testing of a Seismically Isolated Structure
Sarlis, A. A. (author) / Pasala, D. T. R. (author) / Constantinou, Michael C. (author) / Reinhorn, Andrei M. (author) / Nagarajaiah, Satish (author) / Taylor, Douglas P. (author)
2016-01-07
Article (Journal)
Electronic Resource
Unknown
Negative stiffness friction damping for seismically isolated structures
Online Contents | 2006
|Shake table tests on a non-seismically detailed RC frame structure
British Library Online Contents | 2012
|SEISMIC ISOLATION DEVICE, SEISMIC ISOLATION SYSTEM, AND SEISMICALLY ISOLATED STRUCTURE
European Patent Office | 2019
|