Seismic assessment of plan irregular masonry buildings with flexible diaphragms
The seismic Performance-Based assessment of existing masonry buildings requires the use of nonlinear models, in order to check the attainment of ultimate limit states. Incremental Dynamic Analysis represents the most accurate method but very few models areavailable which are able to describe the stiffness and strength degradation, which are typical of masonry buildings, as well as the hysteretic behaviour of piers and spandrels under cyclic actions. At engineering practice level, the Displacement-Based approach is widely adopted, through the use of nonlinear static analysis. However, the application in the case of irregular URM buildings with flexible horizontal diaphragms represents an open issue, due to various difficulties, for example in the transformation of the pushover curve of the original MDOF into the equivalent SDOForinthe definition of performance levels. A wide numerical investigation was made onsome case studies, in order to check the applicability of nonlinear static analyses and propose some newprocedures. Nonlinear dynamic analyses have been adopted as reference solution.
Seismic assessment of plan irregular masonry buildings with flexible diaphragms
The seismic Performance-Based assessment of existing masonry buildings requires the use of nonlinear models, in order to check the attainment of ultimate limit states. Incremental Dynamic Analysis represents the most accurate method but very few models areavailable which are able to describe the stiffness and strength degradation, which are typical of masonry buildings, as well as the hysteretic behaviour of piers and spandrels under cyclic actions. At engineering practice level, the Displacement-Based approach is widely adopted, through the use of nonlinear static analysis. However, the application in the case of irregular URM buildings with flexible horizontal diaphragms represents an open issue, due to various difficulties, for example in the transformation of the pushover curve of the original MDOF into the equivalent SDOForinthe definition of performance levels. A wide numerical investigation was made onsome case studies, in order to check the applicability of nonlinear static analyses and propose some newprocedures. Nonlinear dynamic analyses have been adopted as reference solution.
Seismic assessment of plan irregular masonry buildings with flexible diaphragms
Serena Cattari (author) / Salvatore Marino (author) / Sergio Lagomarsino (author) / Cattari, Serena / Marino, Salvatore / Lagomarsino, Sergio
2015-01-01
Conference paper
Electronic Resource
English
DDC:
621
Seismic Response of Low-Rise Masonry Buildings with Flexible Roof Diaphragms
British Library Conference Proceedings | 2002
|Seismic Response of Irregular Multi-storey Buildings with Flexible Inelastic Diaphragms
British Library Online Contents | 1997
|Seismic Evaluation of Low-Rise Reinforced Masonry Buildings with Flexible Diaphragms