RELIABILITY OF TIMBER STRUCTURES EXPOSED TO FIRE
Until recently, the fire resistance of buildings was based on the ISO standard curve. ISO standard curve used by the current norm is too simple, unrealistic and lead to uneconomic situations with no guarantee of security proportional to the invested money. Unlike the fire design of the steel, concrete or composite structures, methods for fire design of timber structures have been greatly simplified. Generally, it is not necessary to check the reduction of strength in the residual section because each increase of temperature is considered small and it is ignored. Global fire safety concept of timber structures is presented according to the recommendations from Eurocode norms. Special attention was given to natural fire design with two different methods of parametric exposure which are given in EN1995-1-2.This paper presents reliability analysis of a glulam beam in a case of fire. The limit-state functions for maximum bending stress of glulam beam in fire conditions are formed. Reliability indexes are obtained from the limit state of the beam exposed to 30 min fire. Reliability index in the Eurocodes (reliability class RC2) compared to the calculated reliability indexes obtained by the methods of reduced strength and effective section were described.
RELIABILITY OF TIMBER STRUCTURES EXPOSED TO FIRE
Until recently, the fire resistance of buildings was based on the ISO standard curve. ISO standard curve used by the current norm is too simple, unrealistic and lead to uneconomic situations with no guarantee of security proportional to the invested money. Unlike the fire design of the steel, concrete or composite structures, methods for fire design of timber structures have been greatly simplified. Generally, it is not necessary to check the reduction of strength in the residual section because each increase of temperature is considered small and it is ignored. Global fire safety concept of timber structures is presented according to the recommendations from Eurocode norms. Special attention was given to natural fire design with two different methods of parametric exposure which are given in EN1995-1-2.This paper presents reliability analysis of a glulam beam in a case of fire. The limit-state functions for maximum bending stress of glulam beam in fire conditions are formed. Reliability indexes are obtained from the limit state of the beam exposed to 30 min fire. Reliability index in the Eurocodes (reliability class RC2) compared to the calculated reliability indexes obtained by the methods of reduced strength and effective section were described.
RELIABILITY OF TIMBER STRUCTURES EXPOSED TO FIRE
Stepinac, Mislav (author) / Rajčić, Vlatka (author)
2016-01-18
doi:10.14311/asfe.2015.045
Applications of Structural Fire Engineering; 2015: Proceedings of the International Conference in Dubrovnik, 15 - 16 October, 2015 ; 2570-8074 ; 2336-7318
Article (Journal)
Electronic Resource
English
DDC:
690
RELIABILITY OF TIMBER STRUCTURES EXPOSED TO FIRE
TIBKAT | 2015
|Buckling of timber columns exposed to fire
British Library Online Contents | 2011
|Design of exposed timber structures
British Library Online Contents | 2009
|Design of exposed timber structures
Online Contents | 2009
|