A platform for research: civil engineering, architecture and urbanism
Structural silicone sealants after exposure to laboratory test for durability assessment
During the service life of structural sealant glazing (SSG) facades, the loadbearing capacity of the silicone bonds needs to be guaranteed. Laboratory Tests can assess the durability of SSG-systems based on mechanical characteristics of the bond after simultaneous exposure to both climatic and mechanical loads. This article studies how the material characteristics of two common structural sealants are affected by laboratory and field exposure. Dynamic mechanical Analysis (DMA) confirms a reduction in the dynamic modulus of exposed Silicone samples. Results from thermogravimetric analysis, Fourier-transform infrared spectroscopy, differential scanning calorimetry, and small-angle X-ray scattering/wide-angle X-ray scattering show differences between the two sealants and indicate no/minor changes in the composition and morphology of the laboratory and field exposed sealants. Mechanical characterization methods, such as DMA, and tensile and shear testing of the structural bond, are shown to be sensitive toward the combined climatic and mechanical loadings, and are hence suitable for studying degradation mechanisms of structural sealants.
Structural silicone sealants after exposure to laboratory test for durability assessment
During the service life of structural sealant glazing (SSG) facades, the loadbearing capacity of the silicone bonds needs to be guaranteed. Laboratory Tests can assess the durability of SSG-systems based on mechanical characteristics of the bond after simultaneous exposure to both climatic and mechanical loads. This article studies how the material characteristics of two common structural sealants are affected by laboratory and field exposure. Dynamic mechanical Analysis (DMA) confirms a reduction in the dynamic modulus of exposed Silicone samples. Results from thermogravimetric analysis, Fourier-transform infrared spectroscopy, differential scanning calorimetry, and small-angle X-ray scattering/wide-angle X-ray scattering show differences between the two sealants and indicate no/minor changes in the composition and morphology of the laboratory and field exposed sealants. Mechanical characterization methods, such as DMA, and tensile and shear testing of the structural bond, are shown to be sensitive toward the combined climatic and mechanical loadings, and are hence suitable for studying degradation mechanisms of structural sealants.
Structural silicone sealants after exposure to laboratory test for durability assessment
Wallau, Wilma (author) / Recknagel, Christoph (author) / Smales, Glen Jacob (author)
2021-01-01
Article (Journal)
Electronic Resource
English
Fatigue resistance of structural glazing silicone sealants
British Library Conference Proceedings | 1999
|Creep resistance of structural glazing silicone sealants
British Library Conference Proceedings | 1999
|Laboratory and Exterior Durability of High Performance Acrylic Sealants
British Library Conference Proceedings | 1998
|Durability of building sealants
TIBKAT | 1999
|DURABILITY OF ELASTOMERIC SEALANTS
British Library Online Contents | 2015
|