A platform for research: civil engineering, architecture and urbanism
Failure modes in concrete repair systems due to ongoing corrosion
Corrosion of steel reinforcement is the main cause of deterioration in reinforced concrete structures. It can result in cracking and spalling of the concrete cover. After the damaged cover is repaired, reinforcement corrosion might continue and even accelerate. While the development of the corrosion cell is difficult to control, the damage can be possibly delayed and controlled by use of a suitable repair material. The lattice fracture model is used in this paper to investigate the performance of strain hardening cementitious composite (SHCC) in concrete repair systems exposed to ongoing corrosion. Numerical results were verified by experimental tests when SHCC, nonrein forced material (repair mortar), and commercial repair mortar are used as repair materials. In experiments, reinforcement bars (surrounded by a repair material) were exposed to accelerated corrosion tests. The influence of the substrate surface preparation, the type of repair material, the interface, and the substrate strength on the resulting damage and failure mode of repair systems are discussed. In general, SHCC repair enables distributed cracking with small crack widths, up to several times smaller compared to repair mortar. Furthermore, more warning signs prior to the final failure are present in the SHCC repair system.
Failure modes in concrete repair systems due to ongoing corrosion
Corrosion of steel reinforcement is the main cause of deterioration in reinforced concrete structures. It can result in cracking and spalling of the concrete cover. After the damaged cover is repaired, reinforcement corrosion might continue and even accelerate. While the development of the corrosion cell is difficult to control, the damage can be possibly delayed and controlled by use of a suitable repair material. The lattice fracture model is used in this paper to investigate the performance of strain hardening cementitious composite (SHCC) in concrete repair systems exposed to ongoing corrosion. Numerical results were verified by experimental tests when SHCC, nonrein forced material (repair mortar), and commercial repair mortar are used as repair materials. In experiments, reinforcement bars (surrounded by a repair material) were exposed to accelerated corrosion tests. The influence of the substrate surface preparation, the type of repair material, the interface, and the substrate strength on the resulting damage and failure mode of repair systems are discussed. In general, SHCC repair enables distributed cracking with small crack widths, up to several times smaller compared to repair mortar. Furthermore, more warning signs prior to the final failure are present in the SHCC repair system.
Failure modes in concrete repair systems due to ongoing corrosion
Lukovic, Mladena (author) / Savija, Branko (author) / Ye, Guang (author) / Schlangen, Erik (author) / van Breugel, Klaas (author)
2017-01-01
ADVANCES IN MATERIALS SCIENCE AND ENGINEERING ; ISSN: 1687-8434 ; ISSN: 1687-8442
Article (Journal)
Electronic Resource
English
DDC:
690
Repair Guidance Note 11: Ongoing monitoring of concrete repairs
British Library Online Contents | 2008
|REPAIR GUIDANCE NOTE - Repair Guidance Note 11: Ongoing monitoring of concrete repairs
Online Contents | 2008
|Corrosion inhibitors in concrete repair systems
Online Contents | 2000
|Does the Application of Silane to Concrete Reduce Ongoing Reinforcement Corrosion?
British Library Conference Proceedings | 2003
|CONCRETE CORROSION GLOBAL REPAIR SOLUTIONS
British Library Conference Proceedings | 1997
|