6th April 2009 L'Aquila earthquake, Italy:Reinforced concrete building performance
On 6th April 2009 an earthquake of magnitude M w = 6.3 occurred in the Abruzzo region; the epicentre was very close to the city of L'Aquila (about 6 km away). The event produced casualties and damage to buildings, lifelines and other infrastructures. An analysis of the main damage that reinforced concrete (RC) structures showed after the event is presented in this study. In order to isolate the main causes of structural and non-structural damage, the seismological characteristics of the event are examined, followed by an analysis of the existing RC building stock in the area. The latter issue came under scrutiny after the release of official data about structural types and times of construction, combined with a detailed review of the most important seismic codes in force in the last 100 years in Italy. Comparison of the current design provisions of the Italian and European codes with previous standards allows the main weaknesses of the existing building stock to be determined. Damage to structural and non-structural elements is finally analyzed thanks to photographic material collected in the first week after the event; the main causes of damage are then inferred.
6th April 2009 L'Aquila earthquake, Italy:Reinforced concrete building performance
On 6th April 2009 an earthquake of magnitude M w = 6.3 occurred in the Abruzzo region; the epicentre was very close to the city of L'Aquila (about 6 km away). The event produced casualties and damage to buildings, lifelines and other infrastructures. An analysis of the main damage that reinforced concrete (RC) structures showed after the event is presented in this study. In order to isolate the main causes of structural and non-structural damage, the seismological characteristics of the event are examined, followed by an analysis of the existing RC building stock in the area. The latter issue came under scrutiny after the release of official data about structural types and times of construction, combined with a detailed review of the most important seismic codes in force in the last 100 years in Italy. Comparison of the current design provisions of the Italian and European codes with previous standards allows the main weaknesses of the existing building stock to be determined. Damage to structural and non-structural elements is finally analyzed thanks to photographic material collected in the first week after the event; the main causes of damage are then inferred.
6th April 2009 L'Aquila earthquake, Italy:Reinforced concrete building performance
Ricci, Paolo (author) / de Luca, Flavia (author) / Verderame, Gerardo Mario (author)
2011-02-01
Ricci , P , de Luca , F & Verderame , G M 2011 , ' 6th April 2009 L'Aquila earthquake, Italy : Reinforced concrete building performance ' , Bulletin of Earthquake Engineering , vol. 9 , no. 1 , pp. 285-305 . https://doi.org/10.1007/s10518-010-9204-8
Article (Journal)
Electronic Resource
English
6th April 2009 L’Aquila earthquake, Italy: reinforced concrete building performance
British Library Online Contents | 2011
|Guest editorial: L’Aquila earthquake: seismic sequence of 6th April 2009, Abruzzo, Italy
British Library Online Contents | 2011
|Damage assessment of churches after L’Aquila earthquake (2009)
British Library Online Contents | 2012
|Performance of masonry structures during the 2009 L'Aquila (Italy) earthquake
British Library Conference Proceedings | 2010
|British Library Conference Proceedings | 2010
|