The transmission loss of 203 mm thick prestressed precast concrete hollowcore floors
The transmission loss and impact insulation of floors comprised of 203 mm (8 in) thick precast/prestressed concrete hollowcores slabs were evaluated in the direct floor testing facility at the National Research Council. The first floor of concrete hollowcore slabs had a mass per unit area of 269 kg/m2 without grout and a mass per unit area of 273 kg/m2 once the grout was applied between the slabs. The second floor of concrete hollowcore slabs had a mass per unit area of 301 kg/m2 without grout and a mass per unit area of 305 kg/m2 once the grout was applied between the slabs. This floor was also tested with a 25.4 mm (1") underlayment which was poured directly onto the concrete hollowcore slabs and with a carpet and underpad on the underlayment. ; On the title page: Canadian Precast/Prestressed Concrete Institute ; Sur la page de titre: Canadian Precast/Prestressed Concrete Institute ; Peer reviewed: No ; NRC publication: Yes
The transmission loss of 203 mm thick prestressed precast concrete hollowcore floors
The transmission loss and impact insulation of floors comprised of 203 mm (8 in) thick precast/prestressed concrete hollowcores slabs were evaluated in the direct floor testing facility at the National Research Council. The first floor of concrete hollowcore slabs had a mass per unit area of 269 kg/m2 without grout and a mass per unit area of 273 kg/m2 once the grout was applied between the slabs. The second floor of concrete hollowcore slabs had a mass per unit area of 301 kg/m2 without grout and a mass per unit area of 305 kg/m2 once the grout was applied between the slabs. This floor was also tested with a 25.4 mm (1") underlayment which was poured directly onto the concrete hollowcore slabs and with a carpet and underpad on the underlayment. ; On the title page: Canadian Precast/Prestressed Concrete Institute ; Sur la page de titre: Canadian Precast/Prestressed Concrete Institute ; Peer reviewed: No ; NRC publication: Yes
The transmission loss of 203 mm thick prestressed precast concrete hollowcore floors
Mahn, Jeffrey (author)
2018-03-28
doi:10.4224/23002895
Paper
Electronic Resource
English
sound transmission class , IIC , STC , CPCI , precast concrete , hollowcore