A platform for research: civil engineering, architecture and urbanism
The implications of post-tensioning losses on the seismic response of Pres-Lam frames
Since 2010, twelve post-tensioned timber (Pres-Lam) buildings have been constructed throughout the world. In high seismic areas, Pres-Lam technology typically combines unbonded post-tensioning tendons and supplemental damping devices to provide moment capacity to beam-column, wall-foundation or column-foundation connections. Over time creep within the timber elements leads to losses in post-tensioning forces reducing the connection moment capacity. This paper analyses how different post-tensioning loss scenarios, depending on the beam-column joint detailing, impact the building’s seismic response. Two case study buildings were designed and investigated using the Acceleration Displacement Response Spectrum (ADRS) method and Non-Linear Time History Analysis (NLTHA) to predict seismic performance. These buildings were considered to be located in areas of high and low seismic risk, leading to designs with and without the use of damping devices, respectively. The results show that the building with additional damping responded with similar peak displacements, even under extreme loss scenarios. In comparison, when supplemental damping was not used, peak displacements increased significantly with post tensioning losses.
The implications of post-tensioning losses on the seismic response of Pres-Lam frames
Since 2010, twelve post-tensioned timber (Pres-Lam) buildings have been constructed throughout the world. In high seismic areas, Pres-Lam technology typically combines unbonded post-tensioning tendons and supplemental damping devices to provide moment capacity to beam-column, wall-foundation or column-foundation connections. Over time creep within the timber elements leads to losses in post-tensioning forces reducing the connection moment capacity. This paper analyses how different post-tensioning loss scenarios, depending on the beam-column joint detailing, impact the building’s seismic response. Two case study buildings were designed and investigated using the Acceleration Displacement Response Spectrum (ADRS) method and Non-Linear Time History Analysis (NLTHA) to predict seismic performance. These buildings were considered to be located in areas of high and low seismic risk, leading to designs with and without the use of damping devices, respectively. The results show that the building with additional damping responded with similar peak displacements, even under extreme loss scenarios. In comparison, when supplemental damping was not used, peak displacements increased significantly with post tensioning losses.
The implications of post-tensioning losses on the seismic response of Pres-Lam frames
Granello, Gabriele (author) / Palermo, Alessandro (author) / Pampanin, Stefano (author) / Smith, Tobias (author) / Sarti, Francesco (author)
2018-06-30
doi:10.5459/bnzsee.51.2.57-69
Bulletin of the New Zealand Society for Earthquake Engineering; Vol. 51 No. 2 (2018); 57-69 ; 2324-1543 ; 1174-9857
Article (Journal)
Electronic Resource
English
Reducing Seismic Damage in Steel Frames Using Post-Tensioning
British Library Conference Proceedings | 2002
|The Use of Post-Tensioning to Reduce Seismic Damage in Steel Frames
British Library Conference Proceedings | 2002
|Friction Losses in Unbonded Post-Tensioning Tendons
NTIS | 1986
|Strengthening RC Frames against Disproportionate Collapse by Post-Tensioning Strands
British Library Conference Proceedings | 2018
|