A platform for research: civil engineering, architecture and urbanism
Peningkatan Efisiensi Sistem Pencahayaan Dan Pendingin Gedung Bertingkat Berbasis Green Building
Waste of energy in a building causes increase in operating costs for electricity bills. To solve this problem, a building requires energy management planning. Energy Consumption Intensity (IKE) is used to know the energy requirements usage in buildings. Redesign the lighting and cooling system used a simulation model of room lighting and heat loads using the Dialux simulation software for lighting and DACCS for cooling. The results of energy simulation calculations using the Dialux and DACCS software,lighting that uses energy-efficient lamps and utilizes daylight, with inverter cooling with high coefficient of performance is proven to save energy operating costs of 6,904.32 kWh / month and 82,851.84 kWh / year. The results of the Life Cycle Cost that have been carried out show that the use of the existing system for 5 years costs Rp. 3,014,021,105. By using the redesign system costs Rp. 2,937,693,255. The redesign system can save as much as Rp. 76,327,850.
Peningkatan Efisiensi Sistem Pencahayaan Dan Pendingin Gedung Bertingkat Berbasis Green Building
Waste of energy in a building causes increase in operating costs for electricity bills. To solve this problem, a building requires energy management planning. Energy Consumption Intensity (IKE) is used to know the energy requirements usage in buildings. Redesign the lighting and cooling system used a simulation model of room lighting and heat loads using the Dialux simulation software for lighting and DACCS for cooling. The results of energy simulation calculations using the Dialux and DACCS software,lighting that uses energy-efficient lamps and utilizes daylight, with inverter cooling with high coefficient of performance is proven to save energy operating costs of 6,904.32 kWh / month and 82,851.84 kWh / year. The results of the Life Cycle Cost that have been carried out show that the use of the existing system for 5 years costs Rp. 3,014,021,105. By using the redesign system costs Rp. 2,937,693,255. The redesign system can save as much as Rp. 76,327,850.
Peningkatan Efisiensi Sistem Pencahayaan Dan Pendingin Gedung Bertingkat Berbasis Green Building
Sunarwanto, Eko Suryo (author)
2020-12-01
doi:10.33322/sutet.v10i2.1140
JURNAL ILMIAH SUTET; Vol 10 No 2 (2020): JURNAL ILMIAH SUTET; 57 - 68 ; Sutet; Vol 10 No 2 (2020): JURNAL ILMIAH SUTET; 57 - 68 ; 2656-9175 ; 2356-1505 ; 10.33322/sutet.v10i2
Article (Journal)
Electronic Resource
English
DDC:
690
Sistem Penanggulangan Kebakaran pada Gedung Bertingkat berbasis Arduino Mega2560 dan Aplikasi Map
DOAJ | 2021
|ANALISIS CARA PENINGKATAN DAYA DUKUNG FONDASI DANGKAL PADA KONSTRUKSI GEDUNG BERTINGKAT
BASE | 2020
|Sistem Pencahayaan pada Kantor Sequislife di Gedung Intiland Tower Surabaya
BASE | 2013
|