Investigation of the Performance of a Heat Pump Using Waste Water as a Heat Source
WOS: 000276704700013 ; In this research, a water-water heat pump system using waste water as a heat source, a type that is not often used in Turkey and the World, was experimentally modeled. The experiments were performed under the conditions of simulated waste water temperature values of 20 degrees C, 30 degrees C and 40 degrees C. Inlet and outlet water temperatures of the evaporator and condenser, water flow rates in the evaporator and condenser circuits, pressures at the compressor inlet and outlet and power consumption of the system were measured. The heating coefficients of performance were calculated based on the measurements. It was found that the maximum temperature in the energy storage tank was about 50.6 degrees C. For the heat source temperatures of 20 degrees C, 30 degrees C and 40 degrees C, the heating coefficients of the performance of the system became 3.36, 3.43 and 3.69, respectively, 6 min. after the start time of the experiments and then they were decreased to 1.87, 1.83 and 1.77 with increasing water temperature in the condenser tank. The mean uncertainty value of the measurement parameters was found to be about +/-2.47%. Finally, for the purpose of meeting hot water need as well as floor heating system requirements, it is seen that energy quality level of a waste low grade temperature heat source can be increased by using a heat pump system. ; Selcuk UniversitySelcuk University [06101005] ; This work was supported by the Research Fund of Selcuk University (BAP No: 06101005).
Investigation of the Performance of a Heat Pump Using Waste Water as a Heat Source
WOS: 000276704700013 ; In this research, a water-water heat pump system using waste water as a heat source, a type that is not often used in Turkey and the World, was experimentally modeled. The experiments were performed under the conditions of simulated waste water temperature values of 20 degrees C, 30 degrees C and 40 degrees C. Inlet and outlet water temperatures of the evaporator and condenser, water flow rates in the evaporator and condenser circuits, pressures at the compressor inlet and outlet and power consumption of the system were measured. The heating coefficients of performance were calculated based on the measurements. It was found that the maximum temperature in the energy storage tank was about 50.6 degrees C. For the heat source temperatures of 20 degrees C, 30 degrees C and 40 degrees C, the heating coefficients of the performance of the system became 3.36, 3.43 and 3.69, respectively, 6 min. after the start time of the experiments and then they were decreased to 1.87, 1.83 and 1.77 with increasing water temperature in the condenser tank. The mean uncertainty value of the measurement parameters was found to be about +/-2.47%. Finally, for the purpose of meeting hot water need as well as floor heating system requirements, it is seen that energy quality level of a waste low grade temperature heat source can be increased by using a heat pump system. ; Selcuk UniversitySelcuk University [06101005] ; This work was supported by the Research Fund of Selcuk University (BAP No: 06101005).
Investigation of the Performance of a Heat Pump Using Waste Water as a Heat Source
Kahraman, Ali (author) / Celebi, Alaeddin (author) / Selçuk Üniversitesi
2009-01-01
713
Article (Journal)
Electronic Resource
English
DDC:
690
Experimental Research on Performance of Heat Pump Using Shower Waste Water as Heat Source
British Library Online Contents | 2011
|Water source heat pump unit for recycling waste heat of bathroom wastewater source
European Patent Office | 2021
|Heat pump unit machine room for clean water tank water source heat pump system
European Patent Office | 2023
|