Life Cycle Assessment (LCA) for a DC-microgrid energy system in Fjärås ; Livscykelanalys för ett DC-mikronät energisystem i Fjärås
Application of Photovoltaic PV panels for electricity production has rapidly increased in recent years in Sweden after launching a capital subsidy for PV panel installations in 2009. Kungsbacka municipality’s housing company equipped two groups of buildings in Fjärås with PV systems to generate electricity. The newly built residential buildings are connected to a DC-microgrid, whereas the existing buildings have been equipped with a single PV system. This project conducts a cradle to gate life cycle assessment (LCA) for this DC-microgrid energy system. The main purpose of this project is to determine which parts and processes of the DC-microgrid contribute to highest environmental impact throughout their lifespan from cradle to gate stages. Moreover, this study explores the energy payback time (EPBT) and the cumulative energy demand (CED) for the DC-microgrid. Additionally, this study performs two comparative LCA. First the DC-microgrid is being compared with PV system to determine which system has higher environment impacts, and secondly, the DC-microgrid is being compared with the average electricity mix in Sweden in terms of contribution to environmental impacts. The LCA follows the ISO 14040 framework and the baseline method is applied in order to assess 11 environmental impact categories. Two different functional units are adopted in this study. One is based on installed kilowatt peak (kWp) capacity by which environmental impacts of the PV system are compared with the DC-microgrid system. The other functional unit for this study is 1 kWh of delivered electricity to residential buildings produced by the DC-microgrid system. This functional unit is used exclusively for a stand-alone analysis of the DC-microgrid system in order to make it comparable with other microgrid systems or other systems with different energy sources, such as hydro, wind or nuclear. The results of the stand-alone LCA analysis of the DC-microgrid show that the battery has high contribution in human toxicity and terrestrial ecotoxicity ...
Life Cycle Assessment (LCA) for a DC-microgrid energy system in Fjärås ; Livscykelanalys för ett DC-mikronät energisystem i Fjärås
Application of Photovoltaic PV panels for electricity production has rapidly increased in recent years in Sweden after launching a capital subsidy for PV panel installations in 2009. Kungsbacka municipality’s housing company equipped two groups of buildings in Fjärås with PV systems to generate electricity. The newly built residential buildings are connected to a DC-microgrid, whereas the existing buildings have been equipped with a single PV system. This project conducts a cradle to gate life cycle assessment (LCA) for this DC-microgrid energy system. The main purpose of this project is to determine which parts and processes of the DC-microgrid contribute to highest environmental impact throughout their lifespan from cradle to gate stages. Moreover, this study explores the energy payback time (EPBT) and the cumulative energy demand (CED) for the DC-microgrid. Additionally, this study performs two comparative LCA. First the DC-microgrid is being compared with PV system to determine which system has higher environment impacts, and secondly, the DC-microgrid is being compared with the average electricity mix in Sweden in terms of contribution to environmental impacts. The LCA follows the ISO 14040 framework and the baseline method is applied in order to assess 11 environmental impact categories. Two different functional units are adopted in this study. One is based on installed kilowatt peak (kWp) capacity by which environmental impacts of the PV system are compared with the DC-microgrid system. The other functional unit for this study is 1 kWh of delivered electricity to residential buildings produced by the DC-microgrid system. This functional unit is used exclusively for a stand-alone analysis of the DC-microgrid system in order to make it comparable with other microgrid systems or other systems with different energy sources, such as hydro, wind or nuclear. The results of the stand-alone LCA analysis of the DC-microgrid show that the battery has high contribution in human toxicity and terrestrial ecotoxicity ...
Life Cycle Assessment (LCA) for a DC-microgrid energy system in Fjärås ; Livscykelanalys för ett DC-mikronät energisystem i Fjärås
Hashemi Farzad, Tabassom (author)
2019-01-01
Theses