A platform for research: civil engineering, architecture and urbanism
Connection Temperatures during the Mokrsko Fire Test
The Mokrsko fire test focused on the overall behaviour of the structure, which cannot be observed on the separate elements, and also on the temperature of connections with improved fire resistance. During the test, measurements were made of the temperature of the gas and of the elements, the overall and relative deformations, gas pressure, humidity, the radiation of the compartment to structural element and the external steel column, transport of the moisture through the walls, and also the climatic conditions. The results of the test show the differences between the behaviour of the element and the behaviour of the structure exposed to high temperatures during a fire. The collapse of the composite slab was reached. The results of the numerical simulations using the SAFIR program compared well with the measured temperature values in the structure and also in the connections.
Connection Temperatures during the Mokrsko Fire Test
The Mokrsko fire test focused on the overall behaviour of the structure, which cannot be observed on the separate elements, and also on the temperature of connections with improved fire resistance. During the test, measurements were made of the temperature of the gas and of the elements, the overall and relative deformations, gas pressure, humidity, the radiation of the compartment to structural element and the external steel column, transport of the moisture through the walls, and also the climatic conditions. The results of the test show the differences between the behaviour of the element and the behaviour of the structure exposed to high temperatures during a fire. The collapse of the composite slab was reached. The results of the numerical simulations using the SAFIR program compared well with the measured temperature values in the structure and also in the connections.
Connection Temperatures during the Mokrsko Fire Test
Chlouba, J. (author) / Wald, F. (author)
2009-01-01
doi:10.14311/1101
Acta Polytechnica; Vol 49, No 1 (2009) ; 1805-2363 ; 1210-2709
Article (Journal)
Electronic Resource
English
DDC:
690
Uncertainties in steel temperatures during fire
British Library Online Contents | 2013
|Shear tab connection with composite beam subjected to transient-state fire temperatures
Emerald Group Publishing | 2019
|British Library Online Contents | 2006
|Reduction of Connection Resistance During Veselí Fire Tests
Emerald Group Publishing | 2015
|Thermal creep of shear tab connection assemblies under transient-state temperatures of fire
Emerald Group Publishing | 2019
|