Optimization of Central Air Conditioning Plant by Scheduling the Chiller Ignition for Chiller Electrical Energy Management
Currently, the demand for electrical energy in homes, buildings, and industry is increasing, in line with population and economic growth. Of course, because of the massive use of electrical energy, it is necessary to increase efficiency. Large shopping malls in some countries are the biggest consume electricity, especially when it comes to cooling systems. Therefore, it is necessary to save energy in shopping centers. Because there are still few tenants and shopping centers that are relatively quiet, the mall's energy consumption is low, so it requires increasing energy-efficient consumption efficiency by optimizing power management and calculating the chiller performance coefficient (COP). This research aims to increase the chiller performance coefficient (COP) to save energy in shopping centers. The optimization method used is to make changes to the chiller ignition schedule when it's used in malls. Through the analysis from this research, it was found that the COP increased to 0.584, and the value before optimization was 6.181. With increasing COP, the chiller performance will increase. The effect of increasing the chiller's performance could optimize the electrical energy efficiency of the chiller in 138.82 kWh/day
Optimization of Central Air Conditioning Plant by Scheduling the Chiller Ignition for Chiller Electrical Energy Management
Currently, the demand for electrical energy in homes, buildings, and industry is increasing, in line with population and economic growth. Of course, because of the massive use of electrical energy, it is necessary to increase efficiency. Large shopping malls in some countries are the biggest consume electricity, especially when it comes to cooling systems. Therefore, it is necessary to save energy in shopping centers. Because there are still few tenants and shopping centers that are relatively quiet, the mall's energy consumption is low, so it requires increasing energy-efficient consumption efficiency by optimizing power management and calculating the chiller performance coefficient (COP). This research aims to increase the chiller performance coefficient (COP) to save energy in shopping centers. The optimization method used is to make changes to the chiller ignition schedule when it's used in malls. Through the analysis from this research, it was found that the COP increased to 0.584, and the value before optimization was 6.181. With increasing COP, the chiller performance will increase. The effect of increasing the chiller's performance could optimize the electrical energy efficiency of the chiller in 138.82 kWh/day
Optimization of Central Air Conditioning Plant by Scheduling the Chiller Ignition for Chiller Electrical Energy Management
Nugraha, Anggara Trisna (author) / Safitri, Lailia Nur (author)
2021-05-29
doi:10.35882/ijeeemi.v3i2.7
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics; Vol 3 No 2 (2021): May; 76-83 ; 2656-8624
Article (Journal)
Electronic Resource
English
DDC:
690
British Library Online Contents | 1994
Thermal Energy Storage Chiller Management
British Library Online Contents | 1996
|Thermal Energy Storage Chiller Management
British Library Conference Proceedings | 1996
|Rethinking Chiller Plant Design
British Library Online Contents | 1998
|Optimizing TES Chiller Management
British Library Online Contents | 1996
|