A platform for research: civil engineering, architecture and urbanism
Analisa Pemampatan Tanah Subgrade Jalan Baru Universitas Islam Nahdlatul Ulama Jepara
The road construction implementation plan must be supported by supporting parameters such as the plan for the construction of a new road at the Islamic University of Nahdlatul Ulama Jepara. One of the supporting parameters is conducting subgrade testing. Usually subgrade tests for roads use several tests to obtain CBR values. However, this study examines soil compression that will occur when loading is carried out. The type of testing performed is a consolidation test in the laboratory. The result of this test is the Compression Index (Cc) value of laboratory Cc = 0.8305. The pre-consolidated stress (Pc) Pc (the maximum stress that the soil has experienced in the past) = 4.8 kg / cm2. P0 (current stress experienced by the soil) = 0.0773 kg / cm2. OCR = 64.6557. Pc> P0 so that the soil from this laboratory test is Over Consolidated. At a load of 0.5 kg get a value of Cv 0.024, a load of 1 kg get a value of Cv 0.048, a load of 4 kg get a value of Cv 0.444, and a load of 8 kg get a value of Cv 0.177. Recompression Index (Cr) Value of laboratory Cr = - 0.4152
Analisa Pemampatan Tanah Subgrade Jalan Baru Universitas Islam Nahdlatul Ulama Jepara
The road construction implementation plan must be supported by supporting parameters such as the plan for the construction of a new road at the Islamic University of Nahdlatul Ulama Jepara. One of the supporting parameters is conducting subgrade testing. Usually subgrade tests for roads use several tests to obtain CBR values. However, this study examines soil compression that will occur when loading is carried out. The type of testing performed is a consolidation test in the laboratory. The result of this test is the Compression Index (Cc) value of laboratory Cc = 0.8305. The pre-consolidated stress (Pc) Pc (the maximum stress that the soil has experienced in the past) = 4.8 kg / cm2. P0 (current stress experienced by the soil) = 0.0773 kg / cm2. OCR = 64.6557. Pc> P0 so that the soil from this laboratory test is Over Consolidated. At a load of 0.5 kg get a value of Cv 0.024, a load of 1 kg get a value of Cv 0.048, a load of 4 kg get a value of Cv 0.444, and a load of 8 kg get a value of Cv 0.177. Recompression Index (Cr) Value of laboratory Cr = - 0.4152
Analisa Pemampatan Tanah Subgrade Jalan Baru Universitas Islam Nahdlatul Ulama Jepara
Saputro, Yayan Adi (author)
2021-04-28
doi:10.35308/jts-utu.v7i1.3331
Jurnal Teknik Sipil dan Teknologi Konstruksi; Vol 7, No 1 (2021): Jurnal Teknik Sipil & Teknologi Konstruksi ; 2502-051X ; 24775258
Article (Journal)
Electronic Resource
English
DDC:
690
FATWA ULAMA NU (NAHDLATUL ULAMA) DAN MUHAMMADIYAH JAWA TIMUR TENTANG HISAB RUKYAT
DOAJ | 2018
|