A platform for research: civil engineering, architecture and urbanism
THE EFFECT OF CFRP REINFORCED CONCRETE CHIMNEY ON MODAL PARAMETERS USING FINITE ELEMENT METHOD
A variety of methods are used in the repair and strengthening of structures. Some of them use traditional materials, but in cases where they are insufficient, new materials are used. Some interventions may take the form of repairs to several elements, while others strengthen thestructure as a whole. CFRP reinforcement method is one of these reinforcement methods.The method of strengthening with CFRP has been used in many studies recently.Therefore, this study was conducted. In this study, as a result of the reinforcement madeby wrapping 2.5mm thick CFRP fabric into the 20m heightconcrete chimneystructure. The differences between modal parametersof the concrete chimneyand CFRP reinforced concrete chimney were compared.These modal parameters are period and mode shapes.The first 5 modes of the situation with and without CFRP were examined with finite element method.A difference of 4.58% -25.32% was observed in the periods of the first 5 modes.Reinforcement with CFRP has been observed to be positive for safety on the concrete chimneys.
THE EFFECT OF CFRP REINFORCED CONCRETE CHIMNEY ON MODAL PARAMETERS USING FINITE ELEMENT METHOD
A variety of methods are used in the repair and strengthening of structures. Some of them use traditional materials, but in cases where they are insufficient, new materials are used. Some interventions may take the form of repairs to several elements, while others strengthen thestructure as a whole. CFRP reinforcement method is one of these reinforcement methods.The method of strengthening with CFRP has been used in many studies recently.Therefore, this study was conducted. In this study, as a result of the reinforcement madeby wrapping 2.5mm thick CFRP fabric into the 20m heightconcrete chimneystructure. The differences between modal parametersof the concrete chimneyand CFRP reinforced concrete chimney were compared.These modal parameters are period and mode shapes.The first 5 modes of the situation with and without CFRP were examined with finite element method.A difference of 4.58% -25.32% was observed in the periods of the first 5 modes.Reinforcement with CFRP has been observed to be positive for safety on the concrete chimneys.
THE EFFECT OF CFRP REINFORCED CONCRETE CHIMNEY ON MODAL PARAMETERS USING FINITE ELEMENT METHOD
SERTAC TUHTA (author) / FURKAN GUNDAY (author) / ANAS M.S. ALIHASSAN (author)
2021-03-10
International Journal of Innovations in Engineering Research and Technology; Vol. 7 No. 1 (2020): IJIERT; 1-6 ; 2394-3696
Article (Journal)
Electronic Resource
English
DDC:
690
THE EFFECT OF CFRP REINFORCED SQUARE STONE CHIMNEY ON MODAL PARAMETERS USING FINITE ELEMENT METHOD
BASE | 2021
|BASE | 2021
|Reinforced concrete chimney construction
Engineering Index Backfile | 1910
|400-Ft. reinforced concrete chimney
Engineering Index Backfile | 1926
Reinforced concrete for chimney construction
Engineering Index Backfile | 1910
|