A platform for research: civil engineering, architecture and urbanism
Limiting flame spread rates in large compartments with visible timber ceilings
The number of tall buildings combining both a visible mass timber structure and large open floor plans is growing rapidly introducing new fire safety challenges. One risk is that of very rapid flame spread in the ceiling, originating from a severe but localized fire, resulting in fires where the majority of large compartments burn simultaneously. Such phenomena have been observed in both tests and accidents, but knowledge of effective mitigation without the use of sprinklers is scarce. In Europe, this problem is commonly addressed in construction by complying to prescriptive rules of reaction-to-fire classification of linings. The reaction-to-fire classification, primarily based on the single burning item (SBI) test of EN13832, characterizes the material’s contribution to a fire in the very initial phase of the fire. Treatments can be used to improve the reaction-to-fire class of mass timber, which will reduce the risk of substantial fire development. Fires can, however, develop and grow large even without the contribution of lining materials. For this reason, and in light of the recent findings of research of large open floor plan compartments, it is of interest to assess the effectiveness of treatments to reduce the risk of rapid flame spread. Therefore, eight tests in 18.0 × 2.3 × 2.2 m3 compartments were performed. Six had exposed timber surface with a clear coating or impregnation in the ceiling, complying with a reaction-to-fire class B and two served as untreated timber and non-combustible reference tests. The fire source, representing a fire in moveable fuel, was severe enough (3 - 3.7 MW) for flame impingement on the ceiling. The rate of at which wood ignited from the heat in the ceiling, the temperature development at different heights, as well as external flaming were assessed and were used as indicators of performance. Additional indicators were the estimated tenability and ceiling char depths throughout the compartment. The untreated timber and the non-combustible ceiling represented the two ...
Limiting flame spread rates in large compartments with visible timber ceilings
The number of tall buildings combining both a visible mass timber structure and large open floor plans is growing rapidly introducing new fire safety challenges. One risk is that of very rapid flame spread in the ceiling, originating from a severe but localized fire, resulting in fires where the majority of large compartments burn simultaneously. Such phenomena have been observed in both tests and accidents, but knowledge of effective mitigation without the use of sprinklers is scarce. In Europe, this problem is commonly addressed in construction by complying to prescriptive rules of reaction-to-fire classification of linings. The reaction-to-fire classification, primarily based on the single burning item (SBI) test of EN13832, characterizes the material’s contribution to a fire in the very initial phase of the fire. Treatments can be used to improve the reaction-to-fire class of mass timber, which will reduce the risk of substantial fire development. Fires can, however, develop and grow large even without the contribution of lining materials. For this reason, and in light of the recent findings of research of large open floor plan compartments, it is of interest to assess the effectiveness of treatments to reduce the risk of rapid flame spread. Therefore, eight tests in 18.0 × 2.3 × 2.2 m3 compartments were performed. Six had exposed timber surface with a clear coating or impregnation in the ceiling, complying with a reaction-to-fire class B and two served as untreated timber and non-combustible reference tests. The fire source, representing a fire in moveable fuel, was severe enough (3 - 3.7 MW) for flame impingement on the ceiling. The rate of at which wood ignited from the heat in the ceiling, the temperature development at different heights, as well as external flaming were assessed and were used as indicators of performance. Additional indicators were the estimated tenability and ceiling char depths throughout the compartment. The untreated timber and the non-combustible ceiling represented the two ...
Limiting flame spread rates in large compartments with visible timber ceilings
Brandon, Daniel (author) / Sjöström, Johan (author) / Just, Alar (author) / Li, Tian (author) / van Mierlo, Rudolf (author) / Shettihalli Anandreddy, Vikas (author) / Robijn-Meijers, Patries (author)
2023-01-01
2023:131
Paper
Electronic Resource
English
Retrofitting of Timber Beam Ceilings with the Timber-Concrete Composite Construction
British Library Conference Proceedings | 2010
|Retrofitting of Timber Beam Ceilings with the Timber-Concrete Composite Construction
Trans Tech Publications | 2010
|Flame Spread Along a Timber Wall with External Fuel Source
British Library Conference Proceedings | 1995
|