Performance evaluation of CWH base isolated building during two major earthquakes in Christchurch
The seismic performance and parameter identification of the base isolated Christchurch Women’s Hospital (CWH) building are investigated using the recorded seismic accelerations during the two large earthquakes in Christchurch. A four degrees of freedom shear model is applied to characterize the dynamic behaviour of the CWH building during these earthquakes. A modified Gauss-Newton method is employed to identify the equivalent stiffness and Rayleigh damping coefficients of the building. The identification method is first validated using a simulated example structure and finally applied to the CWH building using recorded measurements from the Mw 6.0 and Mw 5.8 Christchurch earthquakes on December 23, 2011. The estimated response and recorded response for both earthquakes are compared with the cross correlation coefficients and the mean absolute percentage errors reported. The results indicate that the dynamic behaviour of the superstructure and base isolator was essentially within elastic range and the proposed shear linear model is sufficient for the prediction of the structural response of the CWH Hospital during these events.
Performance evaluation of CWH base isolated building during two major earthquakes in Christchurch
The seismic performance and parameter identification of the base isolated Christchurch Women’s Hospital (CWH) building are investigated using the recorded seismic accelerations during the two large earthquakes in Christchurch. A four degrees of freedom shear model is applied to characterize the dynamic behaviour of the CWH building during these earthquakes. A modified Gauss-Newton method is employed to identify the equivalent stiffness and Rayleigh damping coefficients of the building. The identification method is first validated using a simulated example structure and finally applied to the CWH building using recorded measurements from the Mw 6.0 and Mw 5.8 Christchurch earthquakes on December 23, 2011. The estimated response and recorded response for both earthquakes are compared with the cross correlation coefficients and the mean absolute percentage errors reported. The results indicate that the dynamic behaviour of the superstructure and base isolator was essentially within elastic range and the proposed shear linear model is sufficient for the prediction of the structural response of the CWH Hospital during these events.
Performance evaluation of CWH base isolated building during two major earthquakes in Christchurch
Zhou, Cong (author) / Chase, J. Geoffrey (author) / Rodgers, Geoffrey W. (author) / Kuang, Adam (author) / Gutschmidt, Stefanie (author) / Xu, Chao (author)
2015-12-31
doi:10.5459/bnzsee.48.4.264-273
Bulletin of the New Zealand Society for Earthquake Engineering; Vol. 48 No. 4 (2015); 264-273 ; 2324-1543 ; 1174-9857
Article (Journal)
Electronic Resource
English
DDC:
690
Telecommunication Systems' Performance: Christchurch Earthquakes
Online Contents | 2014
|Dynamic Behavior of a Base Isolated Building During Earthquakes
British Library Conference Proceedings | 1995
|British Library Online Contents | 2016
|Performance of Base-Isolated Building Frame for Extreme Earthquakes
Springer Verlag | 2018
|