A platform for research: civil engineering, architecture and urbanism
Thermal & structural performance of a cast in place reinforced concrete balcony thermal break
This thesis evaluates the performance of a balcony thermal break when reinforced with carbon steel, stainless steel, or glass fiber reinforced polymer (GFRP). Thermal experimental testing was performed along with three-dimensional finite element modelling to quantify the heat transfer through each variation of the system. Structural experimental testing was performed to assess the ultimate load capacity and serviceability performance of the thermal breaks. The experimental results indicated that the GFRP reinforced system provided the best thermal performance, providing the most significant reduction in heat transfer through the balcony system. The structural experimental results found that all three of the thermal break variations satisfied the ultimate strength requirements as designed. The deflection of the cantilevered balcony was least impacted by the presence of the thermal break when GFRP reinforcement was used, indicating that GFRP is also the preferred reinforcement type for structural requirements. ; February 2019
Thermal & structural performance of a cast in place reinforced concrete balcony thermal break
This thesis evaluates the performance of a balcony thermal break when reinforced with carbon steel, stainless steel, or glass fiber reinforced polymer (GFRP). Thermal experimental testing was performed along with three-dimensional finite element modelling to quantify the heat transfer through each variation of the system. Structural experimental testing was performed to assess the ultimate load capacity and serviceability performance of the thermal breaks. The experimental results indicated that the GFRP reinforced system provided the best thermal performance, providing the most significant reduction in heat transfer through the balcony system. The structural experimental results found that all three of the thermal break variations satisfied the ultimate strength requirements as designed. The deflection of the cantilevered balcony was least impacted by the presence of the thermal break when GFRP reinforcement was used, indicating that GFRP is also the preferred reinforcement type for structural requirements. ; February 2019
Thermal & structural performance of a cast in place reinforced concrete balcony thermal break
2019-01-14
Theses
Electronic Resource
English
Advanced Thermal Performance Analysis of Thermal Break Element Applied in Balcony Slab
British Library Conference Proceedings | 2014
|