A platform for research: civil engineering, architecture and urbanism
Fire Safety Challenges of Tall Wood Buildings – Phase 2: Task 5 – Experimental Study of Delamination of Cross Laminated Timber (CLT) in Fire
Recent architectural trends include the design and construction of tall buildings with visible structural members comprised of mass timber. Cross-laminated timber (CLT) is such a material and is increasingly used for tall buildings because of a combination of advantages regarding its structural performance, low environmental impact and more. As timber is a combustible material, CLT can become involved in the fire at locations where it is not protected against the fire. In that case, the CLT contributes to the fuel load of the fire and has an influence on the fire dynamics. Recent compartment fire tests have shown that bond line failures within cross-laminated timber caused by fire can result in sustained fires that do not extinguish naturally. Due to weakening of the bond line, glued lamellas of the exposed layer of the CLT can delaminate, which can result in a sudden exposure of cold timber to the high temperatures of a fire. This delamination results, therefore, in an increased combustion of exposed timber, and was previously shown to be the cause of continuous fully developed fires and fires that re-intensify after a period of decay. The study presented in this report aimed to (1) determine whether delamination in compartment fires can be avoided by using robust adhesives and (2) to assess the capability of a small scale test method to identify robust adhesives that do not lead to delamination of CLT in fires. The study involved a replication of fire conditions recorded in a recent compartment fire test performed earlier for this research project on Fire Safety Challenges of Tall Wood Buildings. These fire conditions were replicated in an intermediate scale furnace test with an exposed CLT specimen. The fire temperatures, oxygen concentration, incident radiant heat flux, CLT temperatures, charring rate and times of delamination resulting from the intermediate scale tests were similar to those of the compartment test, if the same CLT product was used in both specimens. It was shown that some CLT specimens made ...
Fire Safety Challenges of Tall Wood Buildings – Phase 2: Task 5 – Experimental Study of Delamination of Cross Laminated Timber (CLT) in Fire
Recent architectural trends include the design and construction of tall buildings with visible structural members comprised of mass timber. Cross-laminated timber (CLT) is such a material and is increasingly used for tall buildings because of a combination of advantages regarding its structural performance, low environmental impact and more. As timber is a combustible material, CLT can become involved in the fire at locations where it is not protected against the fire. In that case, the CLT contributes to the fuel load of the fire and has an influence on the fire dynamics. Recent compartment fire tests have shown that bond line failures within cross-laminated timber caused by fire can result in sustained fires that do not extinguish naturally. Due to weakening of the bond line, glued lamellas of the exposed layer of the CLT can delaminate, which can result in a sudden exposure of cold timber to the high temperatures of a fire. This delamination results, therefore, in an increased combustion of exposed timber, and was previously shown to be the cause of continuous fully developed fires and fires that re-intensify after a period of decay. The study presented in this report aimed to (1) determine whether delamination in compartment fires can be avoided by using robust adhesives and (2) to assess the capability of a small scale test method to identify robust adhesives that do not lead to delamination of CLT in fires. The study involved a replication of fire conditions recorded in a recent compartment fire test performed earlier for this research project on Fire Safety Challenges of Tall Wood Buildings. These fire conditions were replicated in an intermediate scale furnace test with an exposed CLT specimen. The fire temperatures, oxygen concentration, incident radiant heat flux, CLT temperatures, charring rate and times of delamination resulting from the intermediate scale tests were similar to those of the compartment test, if the same CLT product was used in both specimens. It was shown that some CLT specimens made ...
Fire Safety Challenges of Tall Wood Buildings – Phase 2: Task 5 – Experimental Study of Delamination of Cross Laminated Timber (CLT) in Fire
Brandon, Daniel (author) / Dagenais, Christian (author)
2017-01-01
NFPA Report number: FPRF-2018-05
Paper
Electronic Resource
English
Fire safety challenges of tall wood buildings. Phase 2: Task 2 & 3: cross laminated
BASE | 2018
|Fire endurance of cross-laminated timber floor and wall assemblies for tall wood buildings
BASE | 2014
|Fire Safety Challenges of Tall Wood Buildings – Phase 2: Task 4 – Engineering Methods
BASE | 2018
|Fire Safety Concept for Tall Timber Buildings
British Library Conference Proceedings | 2008
|