A platform for research: civil engineering, architecture and urbanism
OPTIMIZATION STUDY OF VISUAL COMFORT AND DAYLIGHT AVAILABILITY AT CADL ITB
One way to reduce energy consumption in buildings is to use daylighting. However, daylight can cause visual discomfort in the form of glare. Center of Art, Design, and Language (CADL) Institut Teknologi Bandung is a building that has windows on west and east facades, so the probability of glare occurrence is high. In this research, CADL was optimized so that the percentage of time that Daylight Glare Probability below 0.21 (%DGP<0.21) is more than 50% and spatial daylight autonomy with illuminance 150 lux and 50% (sDA150lux,50%) is more than 30%. In the optimization, vertical blinds, horizontal blinds, and curtains were added. Vertical blinds and horizontal blinds were varied by changing the blade’s opening angle and area covering the windows, while curtains were varied only by changing the area covering the windows. The results show that %DGP<0.21 can be increased beyond 50%, but in some rooms, sDA150,50% also decrease below 30%. The most frequent optimum solutions are vertical blinds 75%-60o.
OPTIMIZATION STUDY OF VISUAL COMFORT AND DAYLIGHT AVAILABILITY AT CADL ITB
One way to reduce energy consumption in buildings is to use daylighting. However, daylight can cause visual discomfort in the form of glare. Center of Art, Design, and Language (CADL) Institut Teknologi Bandung is a building that has windows on west and east facades, so the probability of glare occurrence is high. In this research, CADL was optimized so that the percentage of time that Daylight Glare Probability below 0.21 (%DGP<0.21) is more than 50% and spatial daylight autonomy with illuminance 150 lux and 50% (sDA150lux,50%) is more than 30%. In the optimization, vertical blinds, horizontal blinds, and curtains were added. Vertical blinds and horizontal blinds were varied by changing the blade’s opening angle and area covering the windows, while curtains were varied only by changing the area covering the windows. The results show that %DGP<0.21 can be increased beyond 50%, but in some rooms, sDA150,50% also decrease below 30%. The most frequent optimum solutions are vertical blinds 75%-60o.
OPTIMIZATION STUDY OF VISUAL COMFORT AND DAYLIGHT AVAILABILITY AT CADL ITB
Mhd. Akbar Anthony, SIREGAR (author) / Aflin Tris, HIBATULLAH (author) / Rizki Armanto3, MANGKUTO (author) / R. Triyogo4, ATMODIPOERO (author)
2016-12-01
doi:10.9744/dimensi.43.2.107-114
DIMENSI: Journal of Architecture and Built Environment; Vol 43, No 2 (2016): DECEMBER 2016; 107-114 ; 2338-7858 ; 0126-219X
Article (Journal)
Electronic Resource
English
DDC:
690
OPTIMIZATION STUDY OF VISUAL COMFORT AND DAYLIGHT AVAILABILITY AT CADL ITB
DOAJ | 2016
|Dynamic Façade Design based on Visual Comfort and Daylight Performance Optimization
BASE | 2019
|The Influence of Daylight Availability on Thermal Comfort in Classroom Environments
DOAJ | 2024
|British Library Conference Proceedings | 1994
|