A platform for research: civil engineering, architecture and urbanism
Biurų pastatų naudojant skirtingus šilumnešius vėsinimas ; Cooling of office buildings using different coolants
The final master's work deals with the problem of high energy needs for cooling in office buildings, due to the growing of higher quality requirements for microclimate, higher heat gains in premises and equipment heat emissions used in. To solve the problem four different types of cooling systems with different coolants: air, water and refrigerant are designed at work. Depending on the type of coolant were designed fan coil units, active chilled beams, variable refrigerant volume system and air cooling systems. Air conditioning systems are analyzed on the basis of an example of the real typical office building. The hydraulic and aerodynamic calculations were made, initial investments, energy expenditures and operating costs were estimated for the compared systems. The pay-back time of the systems was assessed and the sensitivity analysis of electricity prices was carried out by economic calculations. The results of this investigation show, which system of all analysed systems at work is the most appropriate for office buildings, according to the efficient use of electricity and the initial investments.
Biurų pastatų naudojant skirtingus šilumnešius vėsinimas ; Cooling of office buildings using different coolants
The final master's work deals with the problem of high energy needs for cooling in office buildings, due to the growing of higher quality requirements for microclimate, higher heat gains in premises and equipment heat emissions used in. To solve the problem four different types of cooling systems with different coolants: air, water and refrigerant are designed at work. Depending on the type of coolant were designed fan coil units, active chilled beams, variable refrigerant volume system and air cooling systems. Air conditioning systems are analyzed on the basis of an example of the real typical office building. The hydraulic and aerodynamic calculations were made, initial investments, energy expenditures and operating costs were estimated for the compared systems. The pay-back time of the systems was assessed and the sensitivity analysis of electricity prices was carried out by economic calculations. The results of this investigation show, which system of all analysed systems at work is the most appropriate for office buildings, according to the efficient use of electricity and the initial investments.
Biurų pastatų naudojant skirtingus šilumnešius vėsinimas ; Cooling of office buildings using different coolants
Kanapienytė, Rasa (author) / Čiuprinskas, Kęstutis
2011-06-13
Theses
Electronic Resource
Lithuanian , English
DDC:
690