Effect of refrigerant mal-distribution in fin-and-tube evaporators on system performance
Refrigerant mal-distribution in fin-and-tube evaporators for residential air-conditioning (RAC) is investigated numerically in this paper. A model of the system is developed in the object-oriented modeling language Modelica. Themodels of the compressor and expansion valve are static, whereas the condenser is a dynamic moving boundary model. The evaporator model is a dynamic distributed one-dimensional homogeneous equilibrium model, in order to capture the distribution phenomena. Fin-and-tube heat exchangers usually have a complex circuitry, however the evaporator will be simplified to be two straight tubes. The refrigerant mal-distribution is then induced to the evaporator by varying the vapor quality at the inlet to each feeder tube, the pressure drop through each feeder tube and the air-flow across each tube. Finally it is shown that air-flow mal-distribution can be compensated by an intelligent distributor, that ensures equal superheat in both tubes. The refrigerant is R410a.
Effect of refrigerant mal-distribution in fin-and-tube evaporators on system performance
Refrigerant mal-distribution in fin-and-tube evaporators for residential air-conditioning (RAC) is investigated numerically in this paper. A model of the system is developed in the object-oriented modeling language Modelica. Themodels of the compressor and expansion valve are static, whereas the condenser is a dynamic moving boundary model. The evaporator model is a dynamic distributed one-dimensional homogeneous equilibrium model, in order to capture the distribution phenomena. Fin-and-tube heat exchangers usually have a complex circuitry, however the evaporator will be simplified to be two straight tubes. The refrigerant mal-distribution is then induced to the evaporator by varying the vapor quality at the inlet to each feeder tube, the pressure drop through each feeder tube and the air-flow across each tube. Finally it is shown that air-flow mal-distribution can be compensated by an intelligent distributor, that ensures equal superheat in both tubes. The refrigerant is R410a.
Effect of refrigerant mal-distribution in fin-and-tube evaporators on system performance
Kærn, Martin Ryhl (author) / Elmegaard, Brian (author) / Larsen, Lars Finn Sloth (author)
2009-01-01
Kærn , M R , Elmegaard , B & Larsen , L F S 2009 , Effect of refrigerant mal-distribution in fin-and-tube evaporators on system performance . in Proceedings of SIMS 50 : Modeling of Energy Technology . Technical University of Denmark , Kgs. Lyngby , pp. 315-322 , 50th International Conference of Scandinavian Simulation Society , Fredericia , Denmark , 07/10/2009 . < http://www.scansims.org/ >
Article (Journal)
Electronic Resource
English
Tube bundle evaporators with LGWP refrigerant R1234ze(E)
Taylor & Francis Verlag | 2024
|Performance comparison of microchannel evaporators with refrigerant R-22
British Library Online Contents | 2007
|Thermodynamic Optimization of Evaporators with Zeotropic Refrigerant Mixtures
British Library Online Contents | 1996
|Thermodynamic Optimization of Evaporators with Zeotropic Refrigerant Mixtures
British Library Conference Proceedings | 1996
|Shell-Side Boiling in Flooded Refrigerant Evaporators Part I: Integral Finned Tubes
Taylor & Francis Verlag | 1995
|