Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.
Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.
Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests
Miyashiro, Mariane (author) / Suedam, Valdey (author) / Moretti Neto, Rafael Tobias (author) / Ferreira, Paulo Martins (author) / Rubo, José Henrique (author)
2011-06-01
Journal of Applied Oral Science; v. 19, n. 3 (2011); 244-248 ; 1678-7765 ; 1678-7757
Article (Journal)
Electronic Resource
English
DDC:
690
Characterization of Biomechanical Performance for Vascular Prosthesis
British Library Online Contents | 2003
|An Active Foot-Ankle Prosthesis With Biomechanical Energy Regeneration
British Library Online Contents | 2010
|British Library Online Contents | 2014
|Zirconia composite ceramic and bone implant prosthesis prepared therefrom
European Patent Office | 2022
|